4.2.2.3 Main display
Spot counter
The user can enable or disable the spot counter. To reset the counter, press the push-button on the right of the display
Test kA/daN
This setting is used to activate or deactivate the clamping force and current settings of the clamp during welding.
The kA/daN control option is activated
and the welding parameters have been
reached.
4.3 OPERATING MODES
Whichever operating mode is selected (Automatic, Synergic, Manual or Manufacturer), welding conditions must be
checked at the start of each job.
«Test» spot welds should be carried out on pieces of sheet metal that are representative of the work being undertaken.
Carry out 2 spot welds spaced at the same distance as those required on the job itself. Test the pulling strength of the
second spot weld. The spot is good when the pulling action causes the core to be torn out of the sheet metal, with a
minimum core diameter in accordance with the vehicle manufacturer's specifications.
Insufficient air pressure
If the input air pressure is insufficient to deliver the required clamping force, the machine will indicate this prior
to the spot with the following error message: «Insufficient air pressure». Pressing the trigger a second time will
«force» the spot, but there is a risk that the required force will not be delivered.
Adaptive Welding function
When the machine is operating in Automatic or Synergic mode, the 'Adaptive Welding' algorithm will adjust the welding
parameters in real time according to the pressure of the compressed air network and the supply voltage.
This function does not work in Manual or Manufacturer mode. We therefore recommend using Automatic or Synergy
mode.
4.3.1 Automatic Mode
This function only works in clamp mode. It is displayed by default when the machine is switched on if there is no gun connected. It allows you to
weld sheet metal without specifying any parameters on the screen. The machine determines the appropriate welding parameters automatically.
Arm change menu
To use this mode, calibration is required at the start, each time the arms or caps are changed, and after every 25 spots.
Translation of the original
instructions
Glue Mode
In Manual and Synergic mode, the user can specify whether glue is present between the plates. When
this mode is in use, a pre-spot is performed before the weld. The duration of this pre-spot is set in
milliseconds, from 0 (OFF) to 400 ms, in 50 ms steps. When glue mode is selected, «Glue» appears
at the bottom of the main screen.
The kA/daN control option is activated and the
welding force has not been reached.
Operating mode
GYSPOT PTI NEO - 400 V
.
Welding without kA/daN Control
Main display
45

Publicité

loading