1. To enter test mode, power the device and hold the button on the controller for 6 seconds until the status LED
begins flashing rapidly.
2. The status LED will indicate the active channel on the tape with a number of flashes followed by a pause. For
example, one flash followed by a pause corresponds to channel 1.
3. Press the button to cycle through all channels and ensure all segments of tape illuminate properly.
4. To exit test mode, hold the button on the controller for 6 seconds until the status LED begins flashing rapidly.
Indicator LED Flash Pattern
LED on the wireless controller is off.
Red LED on the wireless controller
flashes once, then a 2 second pause.
Red LED on the wireless controller
flashes twice, then a 2 second pause.
Red LED on the wireless
controller flashes three times, then
a 2 second pause.
Red LED on the wireless
controller flashes four times, then
a 2 second pause.
Green LED on the wireless controller is
on continuously.
Green LED on the wireless controller
flashes one to five times, then a pause.
®
Lutron Tape Light Solution

Test Mode

Troubleshooting
Reason
No power to the wireless controller or
the controller is already activated on a
system.
Output is short circuited.
Output is overloaded.
Input voltage is too low.
Input voltage is too high.
Device is not commissioned.
Device is in test mode.
10
Remedy
Confirm that the circuit breaker is on to
the power interface and that all wires are
connected to the proper terminals. To
confirm whether the device is receiving
power, follow the steps above to enter
Test Mode and inspect LED feedback.
If needed, devices may be deactivated
using the Lutron App.
Disconnect the LED tape from the
wireless controller and check for shorts.
Cycle power to the wireless controller
to reset.
Confirm that no more than 32.8 ft
(10 m) of LED tape is connected to the
wireless controller output. Cycle power
to the wireless controller to reset.
Confirm that the wireless controller is
being powered by 24 V - ± 10 %.
Activate the device in a system.
Press and hold the button on the
wireless controller for 6 seconds until
the status LED begins flashing to return
to normal operation.