WARNING
• R290 refrigerant gas complies with European environmental directives.
• This appliance contains approximately 0.09 kg of R290 refrigerant gas.
• Use only implements recommended by the manufacturer for defrosting or cleaning.
• Do not use the appliance in a room with continuously operating sources of ignition (eg. Open flames, an
operating gas appliance or an operating electrical heaters.
• Do not perforate any of the components in the refrigerant circuit.
• A surface area greater than 4m² is necessary for the installation, use and storage of the appliance.
• Stagnation of possible leaks of refrigerant gas in unventilated rooms could lead to fire or an explosion hazard
should the refrigerant come in contact with electric heaters, stoves or other sources of ignition.
• Use care when storing the appliance to prevent mechanical faults.
• Only persons authorized by an accredited agency certifying their competence to handle refrigerants in
compliance with sector legislation should work on refrigerant circuits.
• Maintenance and repairs requiring the assistance of other qualified personnel must be carried out under the
supervision of specialists in the use of inflammable refrigerants.
• information for spaces where pipes containing flammable refrigerant are allowed, including
• statements that the installation of pipe-work shall be kept to a minimum;
• that pipe-work shall be protected from physical damage and shall not be installed in an unventilated
space, if that space is smaller than Amin in Annex GG;
• that mechanical connections made in accordance with 22.118, shall be accessible for maintenance
purposes;
• the maximum refrigerant charge amount (M);
• the minimum rated airflow, if required by Annex GG
• An unventilated area where the appliance using flammable refrigerants is installed shall be so constructed
that should any refrigerant leak, it will not stagnate so as to create a fire or explosion hazard.
• The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as
specified for operation
ELECTRICAL CONNECTIONS
• Failure to follow these important safety instructions absolves all liability for the manufacturer.
Before plugging the appliance into the mains socket, ensure that:
• The value indicated on the rating plate must be the same as the mains power supply.
• The power socket and the electrical circuit are sufficient for the appliance.
This product contains flammable
gas R290, hermetically sealed.
Additional warnings for
appliances with R290
refrigerant gas (refer to the
rating plate for the type of
refrigerant gas used)
READ THE MANUAL CAREFULLY
BEFORE USING THE APPLIANCE
This instruction is also available in
an alternative format on website
http://www.erp-equation.com
83
EN

Publicité

loading

Ce manuel est également adapté pour:

2021r08p07-0042D008a-30lD008a-30l cy8887364988873650