8868259
DC VOLTAGE
RANGE
200mV
2,000mV
20V
200V
250V
•
Input impedance: about 10M
•
Results might be unstable at mV range when no load is connected. The value becomes stable
once the load is connected. Least significant digit
•
Max input voltage: ±250V, when the voltage ≥610V, OL symbol appears.
•
Overload protection: 250Vrms (AC/DC)
AC VOLTAGE
RANGE
200V
250V
•
Input Impedance: about 10M
•
Frequency response: 40Hz ~ 400Hz, sine wave RMS (average response).
•
Max input voltage: ±250V, when the voltage ≥610V, OL symbol appears.
•
Overload protection: 250Vrms (AC/DC)
RESISTANCE
RANGE
200Ω
2000Ω
20kΩ
200kΩ
20MΩ
200MΩ
•
Measurement result = reading of resistor - reading of shorted test leads
•
Overload protection: 250Vrms (AC/DC)
4
25 pc Soldering Master Kit
RESOLUTION
0.1mV
1mV
0.01V
0.1V
1V
Ω
,
RESOLUTION
0.1V
1V
Ω
.
RESOLUTION
0.1Ω
1Ω
0.01kΩ
0.1kΩ
0.01MΩ
0.1MΩ
Earth (ground) Terminal
The equipment is protected throughout by
double insulation or reinforced insulation.
ACCURACY
± 0.7% +3
± 0.50% +2
± 0.7% +3
± 0.7% +3
± 0.7% +3
≤
± 3
ACCURACY
± 1.2% +3
± 1.2% +3
For technical questions call 1-800-665-8685
ACCURACY
± (1.0% +2)
± (0.8% +2)
± (0.8% +2)
± (0.8% +2)
± (1.2% +3)
± (5.0% +10)
V1.0