PRO-POINT 8740144 Manuel D'utilisation page 24

Table des Matières
Les langues disponibles

Les langues disponibles

8740144
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does
not function properly or parts are missing. If unable to do so,
have a qualified technician service the tool.
PROBLEM(S)
Tool fails to
work.
Magnetic
base fails to
work, drill
works.
Drill fails to
work,
magnetic
base works.
24
MAGNETIC DRILL
POSSIBLE CAUSE(S)
1. Magnet switch not on.
2. Damaged circuit board
or power supply cord.
3. Power supply failure.
4. The fuse is burnt out.
5. Carbon brushes are
stuck or worn out
6. Defective armature.
7. Defective magnet, ON
or OFF switch.
1. Magnet switch not on.
2. Damaged magnet
switch, electromagnet
or circuit board.
1. Motor switch is not on.
2. Poor contact between
brush and commutator.
3. Damaged motor or
drill armature.
4. Drill chuck/spindle
jammed or damaged.
For technical questions call 1-800-665-8685
SUGGESTED SOLUTION(S)
1. Turn the magnet switch on.
2. Repair or replace the
damaged components.
3. Replace with adequate
power supply.
4. Replace the F2AL 250V
fuse.
5. Inspect and replace
carbon brushes if
necessary.
6. Replace armature.
7. Replace switch.
1. Turn the magnet switch
on.
2. Repair or replace the
damaged components.
1. Turn the motor switch on.
2. Repair or replace the
electric brush.
3. Repair or replace the
hanging the armature or
stator.
4. Replace or repair
chuck/spindle.
V1.0