Safety note indicating possible damage to the
unit/accessory

Important

Serial number
The CE labelling certifies that the product
complies with the essential requirements of Di-
rective 93/42/EEC on medical products
Permissible storage temperature and humidity
Storage
Dispose of packaging in an environmentally
20
friendly manner
PAP

3. Notes

Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to
other users and observe the information they contain.

Safety notes

Warning
• The light of the daylight therapy lamp is only intended for use on the human body.
• Before use, ensure that all packaging materials are removed and that there is no visible damage to the
unit or accessories. When in doubt, do not use the unit and contact your dealer or the customer service
address provided.
• Also ensure that the daylight therapy lamp has a firm footing.
• The mandatory minimum distance between the daylight therapy lamp and flammable objects is 1.0 m.
• Connect the unit only to the mains voltage listed on the type plate.
• Do not dip the unit into water and do not use it in wet rooms.
• Do not use it in the vicinity of people who are helpless, children under age 3 or people who are insensitive
to heat (people with skin lesions due to illness); do not use after taking painkillers or drugs or drinking
alcohol.
• Keep children away from packaging materials (risk of suffocation).
• Do not cover up or pack away the unit while it is warm.
• Always remove the mains plug and let the unit cool off before you touch it.
• Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the
unit. The unit must be operated only when it is completely dry.
• Keep the mains cable away from hot objects and naked flames.
• Protect the unit from strong impacts.
• Do not pull the mains plug from the socket by the cord.
• If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed,
the device must be disposed of.
• Disconnection from the mains supply is only guaranteed if the mains plug has been removed from the
socket.
• Do not use the device in the presence of flammable anaesthetic gas connections with air, oxygen or nitro-
gen oxide.
• No calibration and no preventative checks or maintenance is to be carried out on this device.
• You cannot repair the device. The device contains no parts that you can repair.
• Do not make any changes to the device without the manufacturer's permission.
• If the device has been changed, thorough tests and checks must be carried out to ensure the continued
safety of further use of the device.
• As the patient/user, you can operate all functions of this device.
IP21
Operating
10
Device in protection class 2
OFF / ON
Protected against solid foreign
objects 12.5 mm in diameter
and larger, and against vertical-
ly falling drops of water
Permissible operating tempe-
rature and humidity