Menu Structure
System-specific parameters
Setting for DHW preparation
Sets the desired hot water temperature
Sets the time programs for hot water blocks
Sets the times in which DHW preparation is blocked
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a weekday are activated or deactivated at the end of each
day accordingly.
To carry out a thermal disinfection, the DHW is heated up once to
the desired temperature. The heating period is terminated
automatically when the set temperature is reached, at 12:00 p.m.
or after 4 hours at the latest.
Sets the start time for the thermal disinfection
Sets the desired hot water temperature which is to be reached
during thermal disinfection
For each day of the week, it is possible to select whether thermal
disinfection is desired at the set start time.
Sets the preparation of swimming pool water
Sets the desired swimming pool temperature
Sets the time programs for a priority of swimming pool water
preparation
Sets the start time for the swimming pool priority
Sets the desired number of hours of priority of the swimming pool
water preparation
For each day of the week, it is possible to select whether a priority
is desired at the set start time.
Sets the time programs for swimming pool blocks
Sets the times in which swimming pool water preparation is
blocked
8.1
Setting range
30°C
... 45°C ...
85°C
00:00
...
23:59
N
T1
T2
Y
00:00
...
23:59
60°C
... 65°C ...
85°C
N
Y
5°C
... 25°C ...
60°C
00:00
...
23:59
1
...
10
N
Y
00:00
...
23:59
EN-9