Menu Structure; Settings - Dimplex WPM EconPlus Manuel D'utilisation

Masquer les pouces Voir aussi pour WPM EconPlus:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Menu Structure

8 Menu Structure

8.1 Settings

All user settings are made in the "Settings" menu item.
The following table shows not only the menu structure and
explanations
in
the
right-hand
corresponding setting ranges. Values in bold print indicate the
factory settings.
You can access the settings menu by:
Pressing the button (MENU) for approx. 5 seconds
Select the menu item SETTINGS with the arrow buttons and
confirm with the ENTER button (
column,
but
also
the
).
System-specific parameters
Menu for setting the time. An automatic changeover from daylight
saving time (summer) to winter time can be selected.
Level for setting operating modes
Selects the operating mode
It is also possible to make changes directly using the mode button.
Duration of party mode in hours
After the set period has elapsed, the system returns automatically
to automatic operation again. The value for the raise is set in the
menu "Heating circuit 1 - Raise".
Duration of vacation mode in days
After the set period has elapsed, the system returns automatically
to automatic operation again. The value for the lowering is set in
the menu "Heating circuit 1 - Lower".
Settings for heating circuit 1
Sets the desired room set temperature when room temperature
regulation is selected
Settings to lower the heating characteristic curve of heating circuit
1
Sets the times during which the temperature in heating circuit 1 is
to be lowered.
Sets the temperature value by which the heating characteristic
curve of heating circuit 1 is to be lowered when the temperature is
lowered
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a weekday are activated or deactivated at the end of each
day accordingly.
Settings to raise the heating characteristic curve of heating circuit
1
Sets the time during which the temperature in heating circuit 1 is to
be raised.
NOTE
Dynamic menus
The following contains a description of the complete menu. During start-
up, the regulatory functions and the menu structure are adjusted to the
specific system. Non-relevant menu items are then hidden according to
these settings.
Example: Settings for DHW preparation can only be made if the "DHW
preparation" menu item is configured with "Yes" in the preconfiguration.
Abbreviations:
HG2 = 2nd heat generator (e.g. boiler)
8.1
Setting range
International 24 h
display
Summer
Auto
Party
Vacation
HG2
Cooling
0
... 4 ...
72
0
... 15 ...
150
15.0°C
... 20.0 °C ...
30.0°C
00:00
...
23:59
0K
...
19K
N
T1
T2
Y
00:00
...
23:59
EN-7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wpm econr

Table des Matières