13. SHUTDOWN FOR EXTENDED PERIODS / FOR WINTER

1) Turn off the complete filtration equipment.
2) Drain the pH injection heat contactor.
PH PROBE AND ORP PROBE :
• Never store the probe in distilled water.
• Never touch the bulb of the probe.
3) Equip yourself with : - the storage vial initially mounted on the probe (see visuals in chapters 6.7 and 6.8),
3) Equip yourself with :
3) Equip yourself with :
3) Equip yourself with :
3) Equip yourself with :
4) Disconnect the probe.
5) Remove the probe from the probe holder.
6) Soak the probe for 1 hour in the container of hydrochloric acid.
7) Rinse the probe with tap water, without wiping it afterwards.
8) Soak the probe for 1 hour in the container of bleach.
9) Rinse the probe with tap water, without wiping it afterwards.
10) Place the probe on a clean surface.
11) Fill the storage vial with KCl solution.
12) Insert the probe head into the storage vial.
13) Tidy away and store the probe in a warm, dry place, positioning it vertically, with the bulb facing downwards.
14) Remove the nut from the probe holder and replace it with the cap provided, using sealing tape.
Properties and conditions of use of the cell :
• When the water temperature descends below 15°C, its chemical properties cause premature wear to the cell.
In this situation, turn off the electronics unit.
• The water in the cell must not freeze under any circumstances.
• Provided the cell is not connected to a power supply, leaving it installed on the pipework poses no risk of
deterioration. In this instance, carry out a suitable chemical treatment, preferably without the use of stabilisers.
I
- the cap supplied (see visual in chapter 4),
- a container filled with 10% hydrochloric acid (for the removal of scale),
- a container filled with 2.6% bleach (for the removal of organic matter),
- a suitable KCl solution (for the preservation of the probe).