Allows you to carry out a
pH Regulation
Calibration
calibration of the pH probe.
Allows you to set the pH
pH Regulation
Setpoint
X.X
value.
Allows you to enter the
pH Regulation
Corrector XXXXX
type of pH corrector used.
Allows you to access the
Menu
various 'Parameters'
Parameters
menus.
Parameters
Allows you to set the date.
Date
XX/XX/XX
Parameters
Allows you to set the time.
Time
XX:XX
Allows you to change the
Parameters
Languages
EN
display language.
Allows you to specify the
Parameters
3
Volume
XXX m
volume of the pool.
Allows you to
activate/disable
each function (flap, flow,
salt, temperature).
Parameters
Allows you to select the
Sensors
type of switch for the flap
and flow sensors.
Production operation with a flap position switch:
- When the flap is closed, production is reduced by 80 % in relation to the set value.
In the "%" and "ORP" operating mode, the message " Cover " is displayed instead of the production setpoint.
- When the flap is open, production follows the operating mode as displayed on the screen.
Used to adjust the
measurement of the water
temperature (see chapter
9).
Parameters
Temp. Adjust
→ If the temperature
function is disabled, this
menu will not appear.
Used to adjust the
measurement of the salt
level (see chapter 9).
Parameters
Salt Adjust
→ If the salt levels function
is disabled, this menu will
not appear.
Parameters
Resets the settings.
Restore Param.
Allows you to
activate/disable the Plug &
Parameters
Play function
Code
(as an option for some
DINOTEC COMFORT models).
From 6.6 to 7.6.
- Acidic (pH-)
- Alkaline (pH+)
Day / Month / Year
Hour / Minute
- Français
- English
- Deutsch
- Español
- Italiano
- Nederlander
- Portugués
- Czech
- Turkish
- Polish
From 10 to 200 m
3
(according to the
model),
in steps of 10.
- For pool cover
and flow :
For each function:
OFF.
- ON (to activate)
- For salt and
- OFF (to disable)
temperature :
ON.
For each sensor:
- NO
(switch normally open)
- NC
(switch normally closed)
+ or - 5°C
compared
Measurement
to the value displayed,
displayed
in increments of 1°C.
From 1.5 to 8 g/L,
Measurement
in 0.5 g/L increments.
displayed
7.2
Acidic
See the "Display/Navigation" diagram on page 20.
English
3
50 m
1) Activate the function in question (see row above),
then confirm by pressing and holding N.
NO
2) Select the type of switch.
See the addendum to the user manual
supplied with the Plug & Play kit.
See chapter 12.