6.7. Installing the pH probe

I
The life of the pH probe depends primarily on the strict
observance of all the instructions provided in this manual.
1) Check that the probe bulb is properly immersed in the solution inside the storage vial.
If this is not the case:
a) Remove the storage vial from the probe (see photo below), and keep it for wintering.
b) Rinse the bulb with tap water.
c) Soak the probe for 30 minutes in tap water or in a suitable KCl solution (saturated potassium chloride).
d) Move directly to stage 3).
2) Remove the storage vial from the probe, and keep it for wintering.
I
Never touch the bulb of the probe.
3) Check that there are no air bubbles inside the bulb. If this is not the case, shake the probe by holding the bulb
downwards until the air bubble has risen into the body of the probe.
4) Following the image and the instructions shown opposite :
a) With the use of sealing tape (not supplied), screw the
probe connector
tighten by hand.
b) Loosen nut
A
without removing it.
c) Insert pH probe
20
I
• Do not push the probe as far as the stop-point of
the pipe. Place the probe halfway up accessories
holder 15.
• The probe must be installed :
- after the filter and before any treatment device,
- on the top of the pipe,
- vertically, and on the level (not tilted).
d) Tighten nut
A
by hand.
20
16
15
16
into the accessories holder
into probe holder 16.
16
15
and
20
20
A
16
15
10