4 Programmation
[124]
Fonct. inversé
[125]
Mode manuel
[126]
Mode automatique
5-40 Function Relay
Zone [9]
(Relais 1 [0], Relais 2 [1], Relais 3 [2], Relais 4 [3], Relais 5 [4], Relais 6 [5], Relais 6 [5],Relais 7 [6], Relais 8 [7], Relais 9 [8])
Option:
4
[0] *
No operation
[1]
Control ready
[2]
Drive ready
[3]
Drive rdy/rem ctrl
[4]
Enable / no warning
[5]
VLT running
[6]
Running / no warning
[7]
Run in range/no warn
[8]
Run on ref/no warn
[9]
Alarm
[10]
Alarm or warning
[11]
At torque limit
[12]
Out of current range
[13]
Below current, low
[14]
Above current, high
[15]
Out of speed range
[16]
Below speed, low
[17]
Above speed, high
[18]
Out of feedb. range
[19]
Below feedback, low
[20]
Above feedback, high
[21]
Thermal warning
[22]
Ready,no thermal W
[23]
Remote,ready,no TW
[24]
Ready, Voltage OK
[25]
Reverse
[26]
Bus OK
[27]
Torque limit & stop
[28]
Brake, no brake war
[29]
Brake ready, no fault
[30]
Brake fault (IGBT)
[31]
Relay 123
[32]
Mech brake ctrl
[33]
Safe stop active
[36]
Control word bit 11
[37]
Control word bit 12
[38]
Motor feedback error
62
La sortie est haute dès lors que le variateur de fréquence fonctionne dans le sens antihoraire (produit
logique des bits d'état "fonct." ET "inversé").
La sortie est haute dès lors que le variateur de fréquence est en mode Hand on (comme indiqué
par le voyant LED au-dessus de [Hand on]).
La sortie est haute dès lors que le variateur de fréquence est en mode Auto on (comme indiqué par
le voyant LED au-dessus de [Auto on]).
Fonction:
®
MG.33.AC.04 - VLT
est une marque déposée Danfoss
Manuel d'utilisation du VLT
®
AutomationDrive
FC 300