Preparing a New Sprayer

If this sprayer is new, it is shipped with test fluid in the fluid
section to prevent corrosion during shipment and storage. This
fluid must be thoroughly cleaned out of the system with mineral
spirits before you begin spraying.
IMPORTaNT: always keep the trigger lock on the spray gun
in the locked position while preparing the system.
1. Place the siphon tube into a container of mineral spirits.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure
control knob to the "MIN" setting.
Pump OFF
RAPID
CLEAN
Rapid Clean
4. Move the PRIME/SPRAY valve down to the PRIME position.
5. Turn on the sprayer by moving the ON/OFF switch to the
ON position.
6. Allow the sprayer to run for 15–30 seconds to flush the
test fluid out through the return hose and into the waste
container.
7. Turn off the sprayer by moving the ON/OFF switch to the
OFF position.

Preparing to Paint

Before painting, it is important to make sure that the fluid in the
system is compatible with the paint that is going to be used.
NOTE: Incompatible fluids and paint may cause the
valves to become stuck closed, which would
require disassembly and cleaning of the
sprayer's fluid section.
IMPORTaNT: always keep the trigger lock on the spray gun
in the locked position while preparing the system.
1. Place the siphon tube into a container of the appropriate
solvent. Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.
2. Place the return hose into a metal
waste container.
3. Set the pressure to minimum by
turning the pressure control knob to
the "MIN" setting.
4. Move the PRIME/SPRAY valve down to the PRIME
position.
NOTE: hold the return hose in the waste
container when moving the
PRIME/SPRaY valve to PRIME in
case the sprayer is pressurized.
5. Turn on the sprayer by moving the ON/OFF switch to the
ON position.
6. Allow the sprayer to run for 15–30 seconds to flush the
old solvent out through the return hose and into the metal
waste container.
7. Turn off the sprayer by moving the ON/OFF switch to the
OFF position.
© Titan Tool Inc. All rights reserved.
NOTE: Make sure that the spray gun does not have a tip
8. Move the PRIME/SPRAY valve up to the
9. Turn on the sprayer.
10. Unlock the gun by turning the gun trigger
Pressure
11. Trigger the gun into the metal waste container until the old
Indicator
Pressure
12. Lock the gun by turning the gun trigger
Control Knob
13. Set down the gun and increase the
14. Check the entire system for leaks. If
15. Follow the "Pressure Relief Procedure" in this manual

Painting

1. Place the siphon tube into a container of paint.
2. Place the return hose into a metal
3. Set the pressure to minimum by
4. Move the PRIME/SPRAY valve down to
5. Turn on the sprayer by moving the ON/OFF
6. Allow the sprayer to run until paint is
RAPID
CLEAN
7. Turn off the sprayer by moving the ON/OFF switch to the
8. Remove the return hose from the waste container and
9. Move the PRIME/SPRAY valve up to the
10. Turn on the sprayer.
11. Unlock the gun by turning the gun trigger
5
or tip guard installed.
SPRAY position.
lock to the unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.
solvent is gone and fresh solvent is coming out of the gun.
lock to the locked position.
pressure by turning the pressure
control knob slowly clockwise.
leaks occur, follow the "Pressure Relief
Procedure" in this manual before
tightening any fittings or hoses.
before changing from solvent to paint.
Be sure to follow the pressure relief procedure
when shutting down the sprayer for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
waste container.
turning the pressure control knob to
the "MIN" setting.
the PRIME position.
switch to the ON position.
coming through the return hose into the metal waste
container.
OFF position.
place it in its operating position above the container of
paint.
SPRAY position.
lock to the unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.