- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of
pellets.
- Make sure the stove is off when loading pellets.
- The pellet hopper lid must always remain closed; it must only be opened when loading fuel.
- The bags of pellets must be kept at least 1.5 m from the stove.
When the fume temperature rises the maximum value set, the
display will show the message 'MODULA F' and the stove starts
the modulation of the flame authomatically. On the contrary when
the temperature goes over 280°C the display will show the alarm
'ALARM HOT FUMI' and the stove will start the switch-off
procedure.
If the STANDBY mode is activated, the stove is shut down with a
delay time after reaching the SET temperature. Restart occurs
when the room temperature is lower than a certain fixed value with
respect to the room temperature.
During normal operation in work mode, the 'CLEANING FIRE
POT' mode is activated at fixed intervals for a set duration.

4.5 Shutting down

To shut down the stove, just press the button 'P4' for about 2 seconds.
The auger is stopped immediately and the fume extractor is brought to high speed, with the message 'CLEANING
FIRE POT ' displayed; both fume extraction and air ventilation motors remain on until the stove temperature has
lowered sufficiently.
Dialogue box
At the end of the operation the message 'OFF' appears in the dialogue box.
During the shutdown stage the stove cannot be restarted until the fume temperature has fallen below a set value for
a fixed time, with the message 'WAITING COOL' appearing in the dialogue box.
4.6 Menu
Press the button 'P3' (SET) to access the menu; this is divided into various items and levels for accessing the
settings of the electronic controller.
Room temperature
Clock
Output
43
Clock
Room temperature
Dialogue box
Clock
Dialogue box
Button 'P4'
Output
Room temperature
Output
VIOLA 2014