Shutting Down - Last Calor EVA 2016 Manuel D'installation, D'utilisation Et D'entretien

Poêle à granulés mod
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.4 Work
Once the starting phase has been properly accomplished, the stove goes into WORK mode, with the relative word
shown on the display and with the ON/OFF led on. Heating power can be adjusted by pressing button P2 and then
buttons P1 and P2 from the maximum value of 5 to a minimum value of 1.
The stove automatically adjusts the ventilation of hot air according to the set power.
In addition to the power, also the room temperature can be adjusted. Press button P1 and with buttons, P1 and P2
make the desired setting, from a maximum value of 40 °C to a minimum value of 6 °C.
It is possible to set the manual mode "MAN" when going beyond the value of 40°C (in this configuration the stove
will not follow the ambient temperature). On the other hand, when going below 6°C the external thermostat is
activated "T-E", in order to remotely manage the product. To quit the menu push the button P3 or wait for 5 seconds
until the display will automatically go back to the standard visualization.
- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of fuel.
- Make sure the unit is off when loading pellets.
- The pellet hopper cover must always remain closed, to be opened only during fuel loading.
- The bags of pellets must be kept at least 1.5 m away from the stove.
If STANDBY mode is activated, the stove shuts down after a delay of several minutes. Restart occurs after the room
temperature falls below the set value by a few degrees (default 2 °C).
If STANDBY mode is not activated, or if the fume temperature has reached the set maximum value, the LCD display
shows the message MODULATE and the stove activates the flame modulation without any intervention by the user.
If the temperature increases again, above a set limit, the HOT FUMES alarm appears and the stove activates the
shutdown procedure. During normal operation in work mode, the BRAZIER CLEANING mode is activated at fixed
intervals for a fixed duration of several seconds.

4.5 Shutting down

To turn off the stove, press button P3 for a few seconds. The auger is immediately stopped and the fume exhaust
fan goes to high speed, with the message FINAL CLEANING appearing on the display. The fume exhaust and air
ventilation motors will remain on until the stove temperature has fallen sufficiently.
At the end of the operation the message OFF will appear on the display.
During the shutdown phase the stove cannot be restarted until the fume temperature has dropped below a fixed
value for a given time. If the activation button is pressed the message WAITING COOL will be displayed.
4.6 Menu
Press button P1 to access the menu. It is divided into eleven sub-menus for accessing the settings of the electronic
control.The various sub-menus can be scrolled by pressing buttons P1 and P2, and can be accessed by pressing
button P3.
4.6.1 Menu M1 – set clock
Before operating with the stove the current time and date must be set in order to have a reference for possible
chrono programming. The electronic control has a 3-volt lithium battery model CR2032 that gives the internal clock
with own autonomy of more than 4-5 years; if the clock does not keep the time with stove not powered or a series of
zeros appears at restart, battery replacement is necessary: call an authorised service centre.
To set the clock, access the menu by pressing P3 and adjust the time with buttons P1 and P2. Press P3 again to
adjust the minutes, day, month and year.
4.6.2 Menu M2 – enable chrono
For enabling all chrono functions. To enable the chrono, access the first sub-menu ENABLE CHRONO press button
P3 and set it to ON with buttons P1 or P2. The corresponding symbol lights up on the display and programming is
active. The manual controls of the panel and the remote control retain priority with programming.
Access the second sub-menu DAY PROGRAM to enable or disable the daily chrono with buttons P1 and P2. Then
press button P3 to set up to two operation phases delimited by the set times.Access the third sub-menu WEEK
PROGRAM to enable, disable and set the functions of the weekly chrono. Follow the same procedures of the
previous paragraph. Up to four operation phases delimited by the set times and days can be set.
Do the programming carefully, without overlapping the activation and/or deactivation times on the same day in different
programs.
Access the fourth sub-men WEEKEND PROGRAM to enable, disable and set the chrono functions for the weekend.
Follow the same procedures of the previous paragraph.Up to two operation phases delimited by the set times can
be set. Access the fifth sub-menu to exit the chrono menu and access the main one.
To avoid unwanted startup and shutdown operations, activate only one program at a time.
34
EVA-2016

Publicité

Table des Matières
loading

Table des Matières