Signalling
AL 2
Occurs in case of a fume
FUME
temperature detection probe
fault
PROBE
AL 3
Occurs if the probe detects a
high fume temperature
HOT FUMES
AL 4
Occurs when the fume
exhaust fan is faulty
FAN FAIL
AL 5
Pellets do not ignite in the
lighting phase
NO IGNITION
AL 6
The flame goes out during the
NO PELLETS
operation phases
AL 7
Occurs in case of intervention
THERMAL
of the auger duct temperature
safety thermostat.
SAF
In the work phase the stove
AL 8
detects a pressure lower than
NO NEG
the vacuum switch threshold
PRESS
setting
Occurs when the stove has
SERVICE
exceeded 1800 hours of
DUE
operation or 2000 Kg pellet,
since the previous servicing.
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
ALARMS - MESSAGES
Fault
- Probe fault
- The probe is disconnected
from the board
- Overheating due to use of
the stove for too long
- The tangential fan is faulty or
not powered
- Excessive pellet load
- The fume fan is blocked
- The speed control sensor is
faulty
- No power to the fume fan
- The pellet hopper is empty.
- The heater is faulty, dirty or
incorrectly positioned.
- Incorrect pellet load setting.
- The pellet hopper is empty
- The pellet feed gearmotor is
faulty or not powered
- Overheating due to use of
the stove for too long
- Brazier clogged with
excessive accumulated ash
- The combustion chamber is
dirty
- The fume duct is blocked
- The fire door is not closed
- The overpressure valves are
open-jammed
- The vacuum switch is faulty
The stove requires
extraordinary maintenance
Possible causes
40
Cures
Reinstatement operations
must be carried out by a
service centre
- Wait for the stove to cool and
repeat the lighting procedure
- Other reinstatement
operations must be carried out
by a service centre
Reinstatement operations
must be carried out by a
service centre
- Check the presence of
pellets in the hopper.
- Repeat the lighting
procedure
- Other reinstatement
operations must be carried
out by a service centre
- Check the presence of
pellets in the hopper
- Repeat the lighting
procedure
- Other reinstatement
operations must be carried
out by a service centre
Reset the safety thermostat by
pressing the reset button and
repeat the lighting procedure
- Check the cleanness of the
fume duct and the combustion
chamber, hermetic closure of
the door and the overpressure
valve. Then repeat the lighting
procedure
- Other reinstatement
operations must be carried out
by a service centre
The stove continues its normal
operation. It is advisable to
contact a service centre
as soon as possible
EVA-2016