Work Stage - Last Calor VIOLA 2014 Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Status
OFF
START – CLEANING
PREHEAT
PELLET PREFILL
WAITING FLAME
PELLET LOAD
FIRE PRESENT
WORK
MODULATES WORK
BRAZIER CLEANING
WORK
FINAL CLEANING
After a certain time has elapsed, if the fume temperature has not reached the minimum permissible value the stove
goes in alarm status.
- Do not use flammable liquids to light the stove.
- In case of persistent failed lighting, contact the Service Centre.

4.4 Work stage

After the 'STARTUP' stage, the stove goes to the 'WORK' mode which represents the normal operation mode.
The user can adjust the heat output from the max. value of 5 to a min. of 1 with the buttons 'P5' and 'P6'.
As well as adjusting the heat output, it is also possible to adjust the room temperature directly on the control panel
with the buttons 'P1' and 'P2': the display shows the current SET temperature status.
For the ventilation of hot air, the stove automatically regulates the speed according to the set heat output.
Button 'P1'
Button 'P2'
Duration
Devices
Fume
Igniter
exhaust
Clock
Dialogue box
Dialogue box
Conditions for going to next status
Auger
Exch.
After time Pr33
After timePr34
After time Pr40
After timePr41
Fume temperature > Pr13
After time Pr02
Room temperature < SET temperature
Fume temperature < Pr14
Room temperature < SET temperature
Fume temperature < Pr14
Every Pr03
ON/OFF to switch off
(*) Pr39 starts from when fume T.< Pr13
Room temperature
Output set to 4
Room temperature set value
42
Button 'P6'
Button 'P5'
VIOLA 2014