2.4.7 Optional E-Heater
[Operation Instructions]
1.At the commissioning parameter setting page, by touching "Optional E-Heater", the control panel will go to
the corresponding setting page.
2.At the "Optional E-Heater" setting page, it can be set to "1", "2" or "Off".
3.This setting is used to compare with the ambient temperature. Different comparison results are for different
status of the optional electric heater.
[Notes]
●This setting will be memorized upon power failure.
●Neither "Other thermal" or "Optional E-Heater" can be activated at the same time.
●There are two working logics for "Optional E-heater".
Logic 1: the heat pump and the optional electric heater cannot be started at the same time.
Logic 2: the heat pump and the optional electric heater can be started at the same time when the ambient
temperature is lower than T-Eheater.
●Optional E-Heater and water tank heater won't be started together.
Other Thermal Control
Remark
Heat
/
/
/
water
Heat
/
/
/
water
Heat
/
/
Priority=Heat
Priority=Hot
water
water
Heat
/
/
/
water
Heat
/
/
/
water
Heat
/
/
/
water
Available
RT5 temperature sensor
Available
Extra 3-way valve, water tank sensor
Extra 3-way vlave,RT5 temperature sensor,
Available
Water tank sensor
Available
RT5 temperature sensor
Available
Extra 3-way valve, water tank sensor
Extra 3-way vlave,RT5 temperature sensor,
Available
water tank sensor
Available
RT5 temperature sensor
Not available
/
Available
RT5 temperature sensor
Not available
/
Available
/
Available
/
Available
/
Available
/
Available
/
Available
/
Available
/
Available
/
Available
/
COMMISSION  CODE 000048  FUNCTION  Then, scroll down
in the dropdown menu. Optional E-Heater
 select off/1/2 (1 to activate a single 3kW heating element - 2 to
activate both 3kW heating elements)
 select T-Heater (The outside temperature at which you want the
heating elements to activate)  Select Logic 1/Logic 2 (Logic 1: The
heat pump turns off, and the electric backup operates alone - Logic 2:
The electric backup operates with the heat pump) -> Save