●When "Preset mode" has been set to "Hot water" and "Water tank" is to set to "Without", the preset "Hot
water" mode will be automatically switched to "Heat".
●When "Weekly timer" and "Preset mode" both have been set, priority will be given to the latter.
●When the water tank is available, the preset mode can be "Heat", "Cool", or "Hot water"; however, when the
water tank is unavailable, the preset mode can only be "Heat" or "Cool".
●"Start timer" should be earlier than "End timer", otherwise a dialog will pop up, saying "time setting wrong".
●The setting for "Preset mode" will works until it has been canceled manually.
●When "Start timer" is reached, the main unit will perform the preset mode. In this case, mode and temperature
setting are still allowed but will not be saved to the preset mode. When "End timer" is reached, the control panel
will perform OFF operation.
●This function will be memorized upon power failure.
●When "Weather depend" has been activated and the mode for "Preset mode" is set to "Hot water", "Weather
depend" will be deactivated when the setting mode has been switched.
2.2.15 Error reset
[Operation Instructions]
This function is intended to manually clear errors, which then will enable the heat pump to execute the startup
command.
At the function setting page, by touching "Error reset", a choice box will pop up, where by touching "OK" the
error will be reset and by touching "Cancel" the error will not be reset.
[Notes]
●It can be performed only when the control panel is turned off.
2.2.16 WiFi
[Operation Instructions]
At the function setting page, by touching "WiFi", a choice box will pop up, where by touching "OK" , the WiFi
setting will be reset, and by touching "Cancel" the choice box will quit and WiFi will not be reset.
2.2.17 Reset
[Operation Instructions]
At the function setting page, by touching "Reset", a choice box will pop up, where by touching "OK" all user
parameter settings will be reset and by touching "Cancel" it will back to the function setting page.
[Notes]
●This function is allowed only when the control panel has been turned off.
●This function is valid for "Temp. timer", "Clock timer", "Preset mode", "Weekly timer", and "Weather
depend".