ARTHUR MARTIN GAIA Serie Manuel D'utilisation page 74

Publicité

Les langues disponibles

Les langues disponibles

No.
Item
15
C/P limit
16
Address
Refri.
17
recovery
Gate-Ctrl
18
memory
3-Way valve1
19
Hot water
20
control mode
21
SG
Cool control
22
mode
Heat control
23
mode
HWPS Limit
24
Function
Water pump
25
antistall
No.
Full Name
1
T-HP max
2.4.1 Ctrl. state
[Operation Instructions]
The user is allowed to control the operation of the heat pump through taking either the leaving water temperature
or the room temperature as the control target.
Range
[1-125] [127-253]
Without/DHW/AIR
Commissioning Parameters Setting
Display Name
T-HP max
40~55°C
Default
When it is set to "Current limit" or "Power
limit", sub-parameters stated as below can be
set.
• "Value": power or current limit value, which
• "ΔValue min": 1~15%, 5% defaulted, valid
for the Monobloc GA A units.
• "Electric heater": it can be set to "With" or
"Without", which determines if the power
of electric heater should be taken into
account for current/power limit. When other
thermal source or the optional electric
heater of the water tank is equipped, the
corresponding electric heater can be set to
"Standard" or "Field-supplied". Once it is
set to "Field-supplied", power value can
be adjusted. See Section 2.4.14 for more
details. It is valid for the Monobloc
units.
1
Without
It can be set only when the control
Valid for the Monobloc . It can be set only
Valid for the Monobloc. It can be set only
Valid for the Monobloc. It can be set only
Valid for the Monobloc.
There are three limits for highest speeds of the
water pump: high, medium, low.
It can be set only when the control panel is
Water pump antistall interval: 1~12h, 2h
defaulted;
Water pump antistall duration: 10~100s, 30s
defaulted;
Valid for the Monobloc .
Range
104~131°F
50°C/122°F
20
Description
/
/
/
/
Default
Remark