2.3 User Parameter Setting
[Operation Instructions]
1.At the menu page, by touching "PARAMETER", it will back to the parameter setting page, as shown in the
figure below.
2.At the menu setting page, by touching the page turning keys, it is able to switch to the page where the desired
parameter is.
3.After that, this setting will be saved by touching "OK" and then the main unit will run based on this setting.
While this setting will give up by touching "Cancel".
[Notes]
For parameters with different defaults under different conditions, when conditions changes, the default value
also will change as the corresponding condition changes.
All parameters will be memorized upon power failure.
No.
Full Name
Leaving water
1
temperature for cooling
Leaving water
2
temperature for heating
Room temperature for
3
cooling
Room temperature for
4
heating
5
Water tank temperature
Parameter Setting Page
Parameter Setting
Displayed
Range
(°C)
Name
7~25°C
WOT-Cool
5~25°C
20~60°C
WOT-Heat
20~55°C
20~65°C
RT-Cool
18~30°C
RT-Heat
18~30°C
T-water tank
40~80°C
16
Range
Default
(°F)
45~77°F
18℃ /64°F
41~77°F
18℃ /64°F
68~140°F
45℃ /113°F
68~131°F
45°C/113°F
68~149°F
45°C/113°F
64~86°F
24°C/75°F
64~86°F
20°C/68°F
104~176°F
50°C/122°F
Remarks
Unavailable to
heating only units
Applicable to
Monobloc series
units
High-temp series
units
Normal-temp series
units
Applicable to
Monobloc series
units
Unavailable to
heating only units
/
/