At the commissioning parameter setting page, by touching "Ctrl. state", it can be set to "T-water out" or "T-room".
[Notes]
●When "Remote sensor" is set to "With", this setting can be set to "T-water out" or "T-room". When "Remote
sensor" is set to "Without", this setting can only be set to "T-water out".
● This setting will be memorized upon power failure.
2.4.2 2-Way valve
[Operation Instructions]
At the commissioning parameter setting page, by touching "Cool 2-Way valve" or "Heat 2-Way valve", the
control panel will go to the corresponding setting page.
It is optional. When the under-floor heating coils and radiators are used, it can be used to control the
watercourse.
[Notes]
●This setting is unavailable to heating only units.
●Under "Cool", or "Cool + Hot water" mode, "Cool 2-Way valve" will decide the status of the 2-way valve; while
under "Heat" or "Heat + Hot water", "Heat 2-Way valve" will decide the status of the 2-way valve.
●It will be memorized upon power failure.
2.4.3 Solar setting (reserved)
[Operation Instructions]
1.This setting is unavailable to mini chillers.
2.At the commissioning parameter setting page, by touching "Solar setting", the control panel will go to its
submenu page.
3.At the submenu page, "Solar setting" can be set to "With" or "Without".
4.At the submenu page, the "Solar heater" can be set to "On" or "Off".
[Notes]
●This setting can be done no matter if the control panel is turned on or off.
●This setting is allowed only when the water tank is available. When the water tank is unavailable, this setting
will be reserved.
●It will be memorized upon power failure.
Solar Setting