• Kinks due to improper mounting or routing of con-
necting cables.
• Intersections due to overruns of connecting ca-
bles.
• Insulation damage due to pulling out from wall
sockets.
• Cracks due to ageing of insulation.
Such damaged electric connecting cables should not
be used and can be fatal because of the insulation
damage
AC motor 230 V/ 50 Hz
Mains voltage 230 Volt / 50 Hz.
Mains connection and extension cable must have
3-wires = P + N + SL. - (1/N/PE).
Extension cables must have a minimum cross-sec-
tion of 1.5 mm².
The mains connection is secured with a max. 16A
fuse.
16. Maintenance
Caution! Pull out power plug.
• Clean the machine after each work cycle.
• Replace worn out cutting discs.
• Replace damaged protection device
• Dust and pollution must be removed regularly from
the machine. The best way to clean the machine
is with a piece of cloth or brush.
• All moveable parts must be re-lubricated at peri-
odic intervals.
• Do not use any corrosive substances to clean the
plastic.
• The tub (8) and coolant pump (18) must be cleaned
regularly to remove dirt, as otherwise the cooling
of the diamond cutting disc (14) is not guaranteed.
• Re-commission and inspect all safety equipment.
• Maintenance and repair tasks may only be per-
formed by qualified personnel.
Spare-part ordering
Please quote the following in your order for spare
parts:
• Type of device
• Article No. of device
• Ident. No. of device
• Spare Part No. of the required spare part
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Diamond cutting wheels, carbon brush,
table & cutting head guides
* Not necessarily included in the scope of delivery!
32 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
17. Additional instructions for
leakage current circuit-breaker
(Fig 25)
Please observe the following important instructions
on start-up and handling.
Pay attention to the instructions even if you hand
over the product to a third party. Preserve this oper-
ating Instructions manual for subsequent reference.
Safety instructions!
• Arbitrary alteration and/or modification of the prod-
uct is not allowed for safety- and approval reasons
(CE). Never dismantle the product.
• The product is not suitable for handling by chil-
dren. Children cannot assess the risks involved in
handling electrical devices. Therefore, pay special
attention to the presence of children.
• The structure of the product corresponds to Pro-
tection Class 1. Only a proper mains socket with
an earth wire (230V~/50Hz) of the public power
supply should be used.
• In industrial equipment, the Accident Prevention
Specifications of the Federation of Trade Associ-
ations for Electrical Systems and Resources must
be observed.
• In schools, training centres, hobby- and self-help
workshops, the operation of the product must be
monitored responsibly by trained staff.
• Handle the product carefully. Impacts, hits and
drops from even low heights can damage the ma-
chine.
• Never use the product if it is brought from a cold to
a hot room. Under certain circumstances, the re-
sulting condensed water can destroy the product.
• Let the product come to the room temperature,
before connecting it to the mains power supply.
Under certain circumstances, this can take sev-
eral hours.
• Do not hold the product with moist or wet hands.
• Ensure that the Insulation of the entire product is
neither damaged nor destroyed.
• If the product is not operated over long periods,
disconnect it from the mains power supply, pull the
plug out of the socket.
• Avoid the following environmental conditions at the
installation site or during transport:
• Wetness or very high humidity. Extreme cold. Dust
or combustible gases, vapours or solvents. Strong
vibrations.
• Strong magnetic fields as in the vicinity of ma-
chines or loudspeakers.
Start-up of the leakage current circuit-breaker:
• The leakage current circuit-breaker is equipped
with a test button.
• The function should be checked before each start-
up and at regular Intervals (min. once every week).

Publicité

loading

Ce manuel est également adapté pour:

5906708901