SYMBOLOGY
Volts
Alternating Current
Amps
No Load Revolutions per Minute (RPM)
UL Listing for Canada and U.S.
C
US

FUNCTIONAL DESCRIPTION

Shear pin model
1. Twist-lock plug
2. Cord
3. Gear shift lever
4. Water shut-off valve
5. Spindle sleeve
6. Retaining ring
7. Shear pin
8. Nameplate
Clutch model
1
1. Twist-lock plug
2. Cord
3. Gear shift lever
4. Water shut-off valve
5. Threaded spindle
6. Nameplate
8
1
7
6
6
5
Grounded tools require a three wire extension
cord. Double insulated tools can use either a two
or three wire extension cord. As the distance from
the supply outlet increases, you must use a heavier
gauge extension cord. Using extension cords with
inadequately sized wire causes a serious drop in
voltage, resulting in loss of power and possible tool
damage. Refer to the table shown to determine the
required minimum wire size.
The smaller the gauge number of the wire, the greater
the capacity of the cord. For example, a 14 gauge
cord can carry a higher current than a 16 gauge cord.
When using more than one extension cord to make
up the total length, be sure each cord contains at
2
least the minimum wire size required. If you are using
one extension cord for more than one tool, add the
nameplate amperes and use the sum to determine
the required minimum wire size.
Guidelines for Using Extension Cords
• If you are using an extension cord outdoors, be sure
it is marked with the suffix "W-A" ("W" in Canada)
3
to indicate that it is acceptable for outdoor use.
• Be sure your extension cord is properly wired
and in good electrical condition. Always replace a
damaged extension cord or have it repaired by a
qualified person before using it.
• Protect your extension cords from sharp objects,
excessive heat and damp or wet areas.
4
Recommended Minimum Wire Gauge
Nameplate Amps
0 - 2.0
5
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 16.0
2
16.1 - 20.0
* Based on limiting the line voltage drop to five volts at 150%
of the rated amperes.
READ AND SAVE ALL INSTRUCTIONS
3
4
4

EXTENSION CORDS

For Extension Cords*
Extension Cord Length
25'
50'
18
18
18
18
18
18
18
16
16
14
14
12
12
10
FOR FUTURE USE.
75'
100'
150'
18
18
16
18
16
14
16
14
12
14
12
12
12
10
--
10
--
--
--
--
--