Télécharger Imprimer la page

Dimplex DHW 300 Instructions D'installation Et D'utilisation page 35

Chauffee-eau thermodynamique d'intérieur

Publicité

Les langues disponibles

Les langues disponibles

DHW 300D - DHW 300D+
12 Device information
1
Type and order code
2
Design
2.1
Number of units
2.2
Heat source
2.3
Defrosting
2.4
Nominal cylinder volume
2.5
Transfer area of the internal heat exchanger
2.6
Sensor pipe ø
for external sensors
internal
2.7
Installation location
2.8
Cylinder material
2.9
Cylinder insulation
2.10 Nominal cylinder pressure
3
Operating limits
3.1
Heat source operating limit
3.2
Domestic hot water setting range in heat pump operation
4
Flow / sound
4.1
Air flow
4.2
External compression max.
4.3
Air duct connection length max.
4.4
Sound power level
2
4.5
Sound pressure level
5
Dimension/weight and filling quantities
5.1
Dimensions height (min.) x Width x Depth
5.2
Air duct connection diameter
normial width with EPP-ventilating pipe
5.3
Weight (empty)
5.4
Refrigerant R 134a/total filling weight
5.5
GWP value / CO
equivalent
2
5.6
Refrigeration circuit hermetically sealed
6
Electrical connection
6.1
Degree of protection
6.2
Connection voltage
6.3
Connecting cable approx. 2.7 m - 1.5 mm
6.4
Fuse max.
6.5
Power consumption heat pump cos
6.6
Supplementary electrical heating power consumption
6.7
Power consumption max.
6.8
Switch-on current max.
6.9
Heat pump nominal power consumption at 60 °C
6.10 Supplementary electrical heating power consumption
6.11 Power consumption of fan
6.12 Total power consumption max.
7
Hydraulic connection
7.1
Circulation pipe connection
7.2
Domestic hot water outlet connection
7.3
Cold water inlet connection
7.4
Internal heat exchanger connection
8
Performance values
3 4
8.1
Heat-up time
www.gdts.one
1
2
3
451905.66.02 · FD 9912
DHW 300D
litre
2
m
mm
Frost-free
Enamelled steel complying with
DIN 4753
PU with PS cladding
bar
-7 to 35
°C
°C
20 to 60
3
m
/h
Pa
m
dB(A)
dB(A)
mm
1867 x 740 x 776
190 / DN 160
mm
kg
kg
0.95
--- / t
1430 / 1
IP 21
1/N/PE~230 V, 50 Hz
With plug
A
A
A
A
13.5
W
W
1500
W
W
2200
external thread
R 3/4"
external thread
external thread
external thread
09:22
h:min
DHW 300D+
1
Air
yes
285
-
9
Enamelled steel complying with
PU with PS cladding
6
± 1.0 K
20 to 60
325
80
10
60
50
1867 x 740 x 776
160 / DN 160
107
yes
1/N/PE~230 V, 50 Hz
C16
0.8
6.5
9.5
528
58
R1"
R1"
-
English
1
Air
yes
280
1.0
9
Frost-free
DIN 4753
6
-7 to 35
± 1.0 K
325
80
10
60
50
122
0.95
1430 / 1
yes
IP 21
With plug
C16
0.8
6.5
9.5
13.5
528
1500
58
2200
R 3/4"
R1"
R1"
Rp 1"
09:22
EN-15

Publicité

loading

Ce manuel est également adapté pour:

Dhw 300d+