Closing The Device; Taking Into Operation; Maintenance/Servicing; Repairs / Modification - Eaton CROUSE-HINDS GHG 791 01 Mode D'emploi

Masquer les pouces Voir aussi pour CROUSE-HINDS GHG 791 01:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.4

Closing the device/

cover closure
Any foreign matter shall be removed from
the apparatus.
In order to ensure the required minimum
protection category, the cover screws are to be
tightened down (see technical data).
Overtightening might impair the protection
category.
6.5

Taking into operation

Prior to taking the apparatus into operation, the
tests specified in the relevant national
regulations will have to be carried out.
Apart from that, the correct functioning and
installation of the apparatus in accordance with
these operating instructions and other
applicable regulations will have to be checked.
Incorrect installation and use of the junction
boxes can invalidate the guarantee.
10
Explosion protected junction boxes,
type GHG 791 01 and GHG 791 02
7

Maintenance/Servicing

The relevant national regulations which
apply to the maintenance/servicing of
electrical apparatus in explosive atmos-
pheres, shall be observed (IEC/EN 60079-17).
Before opening the enclosure make sure
that the apparatus is disconnected from the
voltage, or take the appropriate protective
measures.
The required maintenance intervals depend on
the respective application and will therefore
have to be determined by the user dependent
on the conditions of use.
When servicing the apparatus, particularly
those parts that are decisive for the type of
protection against explosion, will have to be
checked.
Cleaning:
Because of the risk of an electrostatic
charge, the junction boxes shall only be
cleaned with a damp, non fibrous cloth or
sponge!
When servicing the apparatus, particularly
those parts that are decisive for the type of
protection against explosion, will have to be
checked (e. g. intactness of enclosure, cable
glands, efficacy of the cover gaskets).
If during servicing repairs prove to be neces-
sary, section 8 of these operating instructions
will have to be observed.
8
Repairs / Overhaul /
Modification
Repairs may only be carried out with genuine
EATON / COOPER CROUSE-HINDS spare parts.
Repairs that affect the explosion protection,
may only be carried out by EATON /
COOPER CROUSE-HINDS or a qualified
electrician in compliance with the applicable
national rules
(IEC/EN 60079-19).
Modifications to the apparatus or changes of its
design are not permitted.
9

Disposal / Recycling

When the apparatus is disposed of, the
respective national regulations on waste
disposal will have to be observed.
In order to facilitate the recycling of individual
components, plastic parts have been provided
with the identification mark of the plastic
material used.
Subject to modifications or supplement of the
product range.
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Crouse-hinds ghg 791 02Crouse-hinds série

Table des Matières