OPERATION
Reload Indicator
To indicate that the magazine is almost empty of fasteners, the
workpiece contact will not compress, preventing operation under
usual pressure. Install more fasteners to continue working.
CABLE INSTALLATION
Cable gauge
Single cable
Double stacked cable
14-2
14-3
12-2
12-3
10-2
10-3
Also suitable for use with low voltage cable such as CAT3, CAT5
and Coax.
CLEARING A JAMMED FASTENER
Most jams are caused by a fastener or part of a fastener wedging
between the driver blade and the nail guide. Fastener strips with an
incorrect collation angle or the wrong fastener gauge may cause
continuous jamming.
To clear the jam:
1. Remove battery pack.
WARNING! Always point the stapler away from yourself and
others when installing or removing staples. Failure to do so could
result in injury.
2. Remove fastener strip from magazine.
3. Pull down on the magazine latch and pull magazine away from
the tool.
4. Remove the staple and other debris (use needle-nose pliers if
necessary).
5. Follow the steps under "Required Daily Testing" before restarting
the work.
18
REQUIRED DAILY TESTING
WARNING: To reduce the risk of injury to yourself and
others, test the tool before beginning work each day or if the
tool is dropped, received a sharp blow, been run over, etc.
Complete the following checklist IN ORDER. If the tool does
not work as it should, contact a MILWAUKEE service facility
immediately.
Always point tool away from yourself and others.
1. Remove battery pack.
WARNING! Always point the staple away from yourself and
others when installing or removing staples. Failure to do so could
result in injury.
2. Check all screws, bolts, nuts, and pins on the tool. Any loose
fasteners must be tightened.
3. Pinch the magazine latch and pull magazine out from stapler
(to override the reload indicator). Press the workpiece contact
against a workpiece. It must move smoothly.
4. With the workpiece contact pressed against the workpiece, pull
the trigger. It must move smoothly.
5. Insert battery pack.
6. Make sure the magazine is still pulled out. Holding the workpiece
contact away from the workpiece, pull and hold trigger for 5
seconds. The stapler must not operate. Release the trigger.
7. If all previous tests work properly, set the tool for your work.
Select the operation and load fastener strips.
8. If all tests operate properly, the tool is ready for use. Repeat
these tests before use each day or if the tool is dropped,
received a sharp blow, been run over, jammed, etc.
MAINTENANCE
The ventilation slots of the machine must be kept clear at all times.
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described,
please contact one of our Milwaukee service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the machine type printed as well as the six-digit No. on
the label and order the drawing at your local service agents or
directly at: Techtronic Industries GmbH, Max-Eyth-Straße 10,
71364 Winnenden, Germany.
ENGLISH
SYMBOLS
Please read the instructions carefully before starting
the machine.
CAUTION! WARNING! DANGER!
Remove the battery pack before starting any work on
the machine.
Always wear goggles when using the machine.
Wear ear protectors!
Wear gloves!
Keep hands away!
Do not dispose electric tools, batteries/rechargeable
batteries together with household waste material.
Electric tools and batteries that have reached the end
of their life must be collected separately and returned
to an environmentally compatible recycling facility.
Check with your local authority or retailer for recycling
advice and collection point.
V
Voltage
Direct Current
European Conformity Mark
UK Conformity Mark
Ukraine Conformity Mark
EurAsian Conformity Mark
ENGLISH
19

Publicité

loading