Télécharger Imprimer la page

AfG Berlin COMBI DIRECT RD-305 Serie Instructions D'installation page 28

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTRUCTIONS FOR THE INSTALLATION
3.0-CONTROL AND SAFETY DEVICES
The ovens are equipped with a set of control and safety devices for the electric and hydraulic
circuits.
3.0A 2A fuse:
it is in the auxiliary circuit to protect against short circuiting of the electrical system
and is inside its own support on the contactor's fixing bracket.
3.0B 1A fuse:
it is in the electronic controller's electrical supply circuit, ("Electronic" versions) to
protect against short circuiting and is housed inside its own support on the contactors' fixing
bracket.
3.0D Motor overload protection:
disengages the motor when, for various reasons,
there is an overload.
When the overload protection triggers it stops the
motor and also disconnects the heating elements or
the gas valve.
The probe is reset automatically when motor
temperature drops.
3.0E Oven safety thermostat:
heating element or the gas valve when anomalies
related to overheating occur.
Subsequent re-set will have to be done manually
when causes for thermostat operation have been
determined.
3.0F Door micro switch:
3.0G Thermostat system for condensation of discharge steam (Optional):
Fig. 3.0H
Combi Direct 5 x 2/3 GN / 5-10-15 x 1/1 GN
a thermal probe
disconnects the
it stops the oven working when the door is opened.
solenoid valve controlled by a thermostat whose sensor is
housed in contact with the discharge.
The solenoid valve, via the injector (G), lets cold water
into the drainpipe to condense the steam when a
temperature of 90°C is reached, (Fig. 3.0G).
3.0H Oven relief valve (Optional):
to adjust humidity inside the cooking chamber.
The valve is manually activated acting on the knob (A)
(Fig.3.0H)on top of the door.
3.0I Heart temperature probe:
"Analogic" models and a standard feature with the
"Electronic" models) with a special sensor inserted in the
food to cook you can control the exact temperature right in
the centre.
28
ENGLISH
Fig. 3.0G
it comprises a
(Optional) its job is
(not available in the

Publicité

loading