Télécharger Imprimer la page

AfG Berlin COMBI DIRECT RD-305 Serie Instructions D'installation page 24

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTRUCTIONS FOR THE INSTALLATION
2.2-ELECTRICAL CONNECTION
When the appliance is delivered it is set to work at the voltage given on the rating plate affixed on
the right side of the appliance.
The terminal board used for connecting can be accessed from the right of the appliance, removing
the side panel. Before connecting the cable, remove the steel protection fixed to the ovens base
with its specific screws, (see Fig. 2.2A)insert the cable in the
clamp-connector and then in the terminal board zone,
passing through the hole with the gasket near the terminal
board. Once the electric connection has been carried out,
reassemble the steel protection previously removed.
The specifications of the flexible cable for the electrical
connection should be no lower than those of the type with
rubber insulation H07 RN-F, with the cross section of the
wires as given in the technical data.
Install a circuit breaker of a suitable capacity upstream from
the appliance, making sure it has an opening between the
contacts of at least 3-mm.
It is essential to connect the appliance to an effective earthing
system; (Fig. 2.2) for this purpose the relative terminal with
the symbol
to which the earth wire is to be connected is
on the terminal board.
The effectiveness of the equipotential system of which the appliance is part of, must conform to
current standards. Connect using the screw you find near the power cable's relief cable strain,
Combi Direct 5 x 2/3 GN / 5-10-15 x 1/1 GN
marked with the word EQUIPOTENTIAL.
The Manufacturer declines all and every
responsibility if this important accident
prevention norm is not complied with
24
ENGLISH
Fig. 2.2

Publicité

loading