Hook Up
A manual gas shut-off valve must be installed external to
the appliance, in a location accessible from the front, for
the purpose of shutting of the gas supply.
Plan the installation of the unit so that the power cord,
gas shut-off valve and gas pressure regulator are
accessible from the front of the cabinet.
The supply line must not interfere with the back of the
unit.
Make sure the gas supply is turned off at the manual
shut-off valve before connecting to the appliance.
Countertop Requirements
Note: All measurements given must be precisely
followed. If nonstandard cabinets are used, make sure
they are installed with minimum dimensions shown in
image below.
30" Models
8
36" Models
Mounting Requirements
Use the hold down brackets supplied. See "Install the
Cooktop" section for further details.
Ventilation Requirements
We strongly recommend the installation of ventilation with
the appliance. The appliance must be installed according
to the furnished instructions.
CAUTION
9
The appliance should not be installed with a
ventilation system that blows air downward toward
the burners. This type of ventilation system may
cause ignition and combustion problems with the
gas cooking appliance resulting in personal injury or
unintended operation.