Before You Begin
Tools and Parts Needed
Phillips Head Screwdriver
Precision Flathead Screwdriver
Tape Measure
Teflon Tape (Gas Rated)
Adjustable Wrench or Channel Lock Pliers
Parts Included
Foam Tape
Mounting Brackets (4)
Screws, #10-32 x 2 1/2" (63.8 mm) (4)
Sheet Metal Screws, #8 x 3/8" (9.5 mm) (4)
Washers (4)
Burner Grates (3)
Burners
30" models: (4) or (5)
36" models: (5)
Burner Caps
30" models: (4) or (5)
36" models: (5)
Pressure Regulator
LP Gas Conversion Kit
Note: If parts are missing or damaged, call the number
or write to the address listed on the inside back cover.
General Information
Overall Dimensions
Width (Side to Side)
Depth (Front to Back)
Height (Top to Bottom)
Note: These are overall dimensions NOT cutout
dimensions.
30" Models
36" Models
31"
37"
(788 mm)
(940 mm)
21 1/4"
21 1/4"
(540 mm)
(540 mm)
3 13/16"
3 13/16"
(97 mm)
(97 mm)
Preparation
Electrical Requirements
CAUTION
9
Do not use an extension cord with the gas cooktop.
This appliance requires a 60 Hz, 15 Amp, 120 VAC
connection. Plan the installation so that the power
connection is accessible from the front of the cabinet.
Gas Requirements
Supply Pressure:
Natural Gas: 7 inches water column (14.9 Millibars)
Propane Gas: 11 inches water column (27.4 Millibars)
The propane gas tank must be equipped with its own
high pressure regulator in addition to the pressure
regulator supplied with this unit. The cooktop is shipped
from the factory for use with natural gas. For use with LP
conversion, a certified technician or installer must do the
conversion.
Cabinet Requirements
Instructions are based on standard American cabinets
36" high (91cm) x 24" deep (61cm) with a 25"
(63cm) countertop.
The maximum depth of a cabinet installed above the
cooktop is 13" (33cm).
Note: All measurements given must be precisely
followed. If nonstandard cabinets are used, make sure
they are installed with minimum dimensions shown.