Télécharger Imprimer la page

Bosch NGM5056UC Manuel D'installation page 11

Masquer les pouces Voir aussi pour NGM5056UC:

Publicité

Les langues disponibles

Les langues disponibles

Side View Gas Cooktop Installation
Gas and Electrical Location
Rough-in Cooktop Box
A
Arrow on Pressure Regulator
B
Pressure Regulator
C
1/2" Female Pipe Threads
D
Flexible Gas Line
E
Power Cord (60 inches/1,524mm)
G
120 Volt Receptacle
H
Gas Cut-off Valve
J
Gas Supply Line Stub-out
K
Floor
L
Connect the gas supply line to the unit pressure
regulator using a 1/2" flex gas line connector between
manual shut-off valve and pressure regulator. Always use
a new flex line.
Check supply line connections for leaks using a soap
solution or non-corrosive leak detection fluid. Do not use
a flame of any sort.
Turn on gas.
1.
Apply a soap solution or non-corrosive leak detection
2.
fluid to all joints and fittings in the gas connection
between the shut-off valve and the cooktop. Include
gas fittings and joints in the cooktop if connections
may have been disturbed during installation. Bubbles
appearing around fittings and connections indicate a
leak.
If a leak appears, turn off supply line gas shut-off valve
3.
and tighten connections.
Retest for leaks by turning on the supply line gas shut-
4.
off valve. When leak check is complete (no bubbles
appear), test is complete.
Wipe off all soap solution or detection fluid residue.
5.
Important Notes for Gas Connection:
The appliance and its individual gas shutoff valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psi (3.5kPa).
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psi (3.5kPa).
Connect Electrical Supply
Before connecting the 5-foot (1.5m) supply cord to a wall
receptacle, make certain that gas shut-off valve and all
burner controls are in OFF position.
Burner Cap and Burner Base Placement
WARNING
9
To prevent flare-ups, do not use the cooktop without
all burner caps and all burner grates properly
positioned.
WARNING
9
To prevent burns, do not touch burner caps or
grates while hot. Turn the cooktop off and allow the
entire cooktop to cool.
11