Kongskilde RVS Serie Manuel De Service page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
RVS 10000 S6 CR 50 Hz IEC
121 104 023
3x230V (8,05A)
RVS 10000 S6 OR 50 Hz IEC
121 104 723
3x230V (8,05A)
RVS 10000 S6 CR 60 Hz CUS
121 104 025
3x460V (4,3A)
RVS 10000 S6 CR 60 Hz CUS
121 104 027
3x575V (3,4A)
RVS 10000 S6 OR 60 Hz CUS
121 104 725
3x460V (4,3A)
RVS 10000 S6 OR 60 Hz CUS
121 104 727
3x575V (3,4A)
RVS 20000 S3 CR 50 Hz IEC
121 104 032
3x400V (7,43A)
RVS 20000 S3 OR 50 Hz IEC
121 104 732
3x400V (7,43A)
RVS 20000 S3 OR 60 Hz CUS
121 104 734
3x460V (7,2A)
RVS 20000 S3 CR 60 Hz CUS
121 104 736
3x575V (5,6A)
RVS 20000 S3 CR 60 Hz CUS
121 104 034
3x460V (7,2A)
RVS 20000 S3 CR 60 Hz CUS
121 104 036
3x575V (5,6A)
RVS 20000 S6 OR 50 Hz IEC
121 104 733
3x400V (7,43A)
RVS 20000 S6 CR 50 Hz IEC
121 104 033
3x400V (7,43A)
RVS 20000 S6 CR 60 Hz CUS
121 104 035
3x460V (7,2A)
RVS 20000 S6 CR 60 Hz CUS
121 104 037
3x575V (5,6A)
RVS 20000 S6 OR 60 Hz CUS
121 104 735
3x460V (7,2A)
RVS 20000 S6 OR 60 Hz CUS
121 104 737
3x575V (5,6A)
S3: Ø3 mm holes in sieve
S6: Ø6 mm holes in sieve
CR: Closed rotor (with end sieve)
OR: Open rotor (without end sieve)
12
All manuals and user guides at all-guides.com
400V (4,65A)
400V (4,65A)
690V (4,29A)
690V (4,29A)
690V (4,29A)
690V (4,29A)
Start-up:
0,79
During any test operation, it is recommended to ap-
ply the supplied PTFE spray onto the inner side of the
separator, to avoid unnecessary wear and to reduce
energy consumption of the gear motor.
0,79
Prior to start-up, check:
that there are no foreign objects in the separator
housing or the associated duct system
0,73
that the direction of rotation of the separator's ro-
tor is correct (indicated by the arrow). The motor's
0,73
cooling fan and rotor axle in the motor side rotates
in a clockwise direction. See the rotor axle in oppo-
0,73
site side if in doubt
the oil level in the gear
0,73
that the vent plug is activated by removing the seal-
ing cord
that all parts including protective guards are se-
curely fastened
0,88
To remove the sealing cord from the gear vent plug:
0,88
0,74
0,74
0,74
Operation:
If the separator is clogged or need inspection, the two
0,74
inspection hatches on the upper part can be removed.
This is done by loosening the thumb screws, and slid-
ing the pawls towards the centre of the hatch, where
0,88
after the hatch can be lifted away. At installation of
the hatch, it is important to ensure, that the gaskets
and pawls are correctly seated before tightening the
0,88
thumb screws. In case the hatch does not seal correctly
against the upper part, there is risk of dust pile-up or
other contamination of the separator. On ATEX ver-
0,88
sions, always reinstall the grounding wires securely.
The upper part of the separator can be raised by loos-
0,74
ening/removing the tube connections on both sides of
the separator, and loosening the eye bolts. After this,
0,74
the upper part can be lifted by crane, using the lifting
eyes 1, see illustration. Finally, the upper part can be
secured with the arm 2, where the screw 3 is installed
0,74
with nut on the upper side of the plate. The separators
upper part is closed in reverse sequence.