The control panel
Pic.5 – The control panel
S1 - Green light ON The green light indicates when the dehumidifi-
er is operative, otherwise it blinks on status 0.
S2 - Red light, full tank The light blinks, together with the green one
S1, when the tank is full, missing or incorrectly positioned.
S3 - Yellow light, defrost The light switches on during the automatic
defrosting cycle.
T1 - Decrease button Pushing this button the value of the display D
will decrease down to 0 value.
T2 - Increase button Pushing this button the value of the display D
will increase up to C value.
D - Display The display shows the working state of the dehumid-
ifier according with Tab.B. The value 0 means OFF, from 1 to 9
means automatic functioning and it depends from the humidistat
that switches on or off the dehumidifier if the value of the relative
humidity is higher or lower of the one shown in the Tab.B. The value
C means ALWAYS ON and the dehumidifier works independently
from the humidity value: nevertheless any allarm has the priority on
functioning mode.
Display
Functioning
0
Off
1 ÷ 2
from about 85% to 90% R.H.
3 ÷ 4
from about 70% to 80% U.R.
5 ÷ 6
from about 60% to 65% R.H.
7 ÷ 8
from about 45% to 55% R.H.
9
about to 40% R.H.
C
Continuous
Tab.B – Functioning modes
Start up
When the plug is connected the display D blinks for 5 seconds and
shows the last functioning mode selected: then, if the functioning
mode is different from zero, the blinking stops.
Shutdown
To switch off the dehumidifier push the button T1 until the value
displayed is 0. When zero is selected both the green light S1 and the
display D blink.
The defrosting cycle
If the temperature goes below 16°C ice may form on the evaporator:
le electronic board automatically performs the defrosting cycle to
melt the ice and keep free the air flow even at lower temperatures..
18
All manuals and user guides at all-guides.com
Failures
The display is used by the electronic device to show particular situ-
ations (Tab.C). If an error message is displayed please contact your
dealer for repair.
The hour counter
The dehumidifier is fitted with two hour counters, one resettable and
one not resettable. The hour counter can register up to 999.999,99
functioning hours.
S
To show all the 8 digits the electronic board will show two digits at
a time, hiding the non significant ones: for a correct reading of the
digits see the image below where the number 554.433,22 is supposed
to be shown:
The visualization will automatically stop after one minute or push-
ing the button T3.
S
Hour counter 1, resettable
To show the resettable hour counter:
• push button T3 for tree seconds: the display will show tree
• push the buttons T1 - T1 - T3 in sequence.
Hour counter 2, not resettable
Tho show the whole working hours:
• push button T3 for tree seconds: the display will show tree
• push the buttons T2 - T2 - T3 in sequence.
Reset of the hour counter 1
• push button T3 for tree seconds: the display will show tree
• push the buttons T1 - T2 - T3 - T2 - T1 in sequence;
the number .00 is displayed to confirm the reset.
ENGLISH
Display
Description
ntc
Temperature probe must be checked
und
Humidity probe must be checked
Tab.C – Error messages
The decimal digits are in hours: so 0,50 means 30
minutes. In this way any calculation based on the
working hours is simplified.
Pic.6 – Hour counter cycle
The hour counter does NOT work if the dehumidi-
fier is in functioning mode 0, stand-by or in error.
Only the effective working hours will be registered.
blinking horizontal lines;
blinking horizontal lines;
blinking horizontal lines;