• Do not use corrosive products to clean the floor beneath the
appliance.
• Not wash in the dishwasher the body and the flame sprea-
ders of the burners of the cooking hob.
3 SAFETY AND CONTROL DEVICES
3.1 ELECTRIC AND GAS FRY-TOPS WITH VALVE
SAFETY THERMOSTAT
The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules.
• The appliance is equipped with a manual reset safety ther-
mostat which interrupts heating when the operating tempera-
ture exceeds the maximum permitted value.
• To restore appliance operation, remove the control panel (
the front panel for Boiling pans and Bratt pans ) and press the
thermostat reset button.This procedure must only be carried
out by a qualified, authorized technician.
4 DISPOSAL OF PACKAGING AND THE APPLIANCE
4.1 PACKAGING
The packaging is made using environmentally friendly mate-
rials. The plastic recyclable components are:
• the transparent cover, the bags containing the instructions
manual and nozzles ( made of Polyethylene - PE.).
• the straps (in Polypropylene - PP).
4.2 APPLIANCE
The appliance is manufactured 90% from recyclable metals
(stainless steel, aluminum sheet, copper.... ).
The appliance must be scrapped in compliance with current
regulations governing such disposal.
• It must be disposed of properly.
• Make the appliance unusable before scrapping.
RISKS DUE TO NOISE
• On airborne noise emissions, the A-weighted sound pressure
level is below 70 dB(A).
INSTRUCTIONS FOR INSTALLATION
REMINDERS FOR THE INSTALLER
The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules.
• Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Installation, conversion to a different type of gas and applian-
ce maintenance must be carried out by qualified technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions in this manual.
• Identify the specific appliance model. The model number is
detailed on the packaging and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.
5 REFERENCE STANDARDS AND LAWS
Install the appliance in conformity to current statutory safety
standards.
Install the appliance in compliance with current regulations.
6 UNPACKING
Check the state of the packaging and in the event of damage,
ask the delivery person to inspect the goods.
• Remove the packaging.
• Remove the protective film from the outer panelsand interior.
Use a suitable solvent to remove any residual adhesive from
the panels.
7 POSITIONING
• The overall dimensions of the appliance and the position of
connections are given on the installation diagram at the start
of this manual.
• The appliance can be installed singly or in combination with
other appliances in the same product range.
• The appliance is not suitable for integrated installation.
• Position the appliance at least 10 cm from adjacent walls.
This distance can be reduced in the presence of non-combu-
stible walls or heat-insulated walls.
• Level the appliance by means of the height-adjustable feet.
• The benchtop appliance weighing less than 40 kg, if installed
singularly, it must be fixed using the appropriate flanged feet.
7.1 APPLIANCE ASSEMBLY WITH BASE, BRIDGE, AND
CANTILEVER SOLUTIONS
Follow the instructions provided with the type of support utili-
zed.
7.2 FIXING THE APPLIANCE TO THE FLOOR
Appliances of 40cms in width installed alone must be fixed to
the floor. Use the flanged feet provided.
7.3 JOINING APPLIANCES TOGETHER IN LINE
• Remove the control panels ( A ).
• Place the appliances side by side and adjust the tops to the
same height ( C ).
• Join the appliances by screwing down the connector plate (
B-D ) using the supplied screws.
• Slacken the 2 front screws (E), turn the plate (F) until it
catches the screw of the adjacent appliance.
• Tighten the screws (E).
8 CONNECTIONS
The position and dimensions of connections are given in the
installation diagram at the start of this manual.
8.1 ELECTRICAL CONNECTIONS
Check that the appliance is designed to operate at the voltage
and frequency of the power supply present on site. Check the
details given on the appliance data plate.
The meaning of symbol
WARNING DANGEROUS VOLTAGE.
• Install an adequately rated omnipolar circuit-breaker upline
of the appliance in an easily accessible point, in compliance
with installation regulations; the circuit breaker must guaran-
tee immediate omnipolar disconnection from the mains, with
a minimum contact opening that allows complete disconnec-
tion in overvoltage category III conditions. The maximum per-
mitted current dispersion is 1mA/kW.
• For electrical connection, use a rubber-sheathed flexible ca-
ble which is oil resistant, type H05RN-F or H07RN-F, for ca-
ble size consult the technical data table.
, if used, is: