Télécharger Imprimer la page

Empire Comfort Systems DVCTL60CFP95N Instructions D'installation page 3

Publicité

Les langues disponibles

Les langues disponibles

Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly.
DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED
WARNING
1. "Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies."
2. "Children and adults should be alerted to the hazards
of high surface temperature and should stay away to
avoid burns or clothing ignition."
3. "Young children should be carefully supervised when they
are in the same room as the appliance. Toddlers, young
children, and others may be susceptible to accidental
contact burns. A physical barrier is recommended if there
are at-risk individuals in the house. To restrict access to a
fireplace or stove, install an adjustable safety gate to keep
toddlers, young children, and other at-risk individuals out
of the room and away from hot surfaces."
4. For appliances requiring a barrier, as determined under
Clause 5.15.4: "A barrier designed to reduce the risk of
burns from the hot viewing glass is provided with this
appliance and shall be installed for the protection of
children and other at-risk individuals."
5. "If the barrier becomes damaged, the barrier shall
be replaced with the manufacturer's barrier for this
appliance."
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each appliance
connected to the venting system being placed into operation
could result in carbon monoxide poisoning or death.
The following steps shall be followed for each appliance
connected to the venting system being placed into operation,
while all other appliances connected to the venting system
are not in operation:
1. Seal any unused openings in the venting system.
2. Inspect the venting system for proper size and horizontal
pitch, as required in the National Fuel Gas Code ANSI
Z223.1/NFPA 54 or the National Gas and Propane
Installation Code CSA B149.1 and these instructions.
Determine that there is no blockage or restriction,
leakage, corrosion and other deficiencies which could
cause an unsafe condition.
3. As far as practical, close all building doors and windows
and all doors between the space in which the appliance(s)
connected to the venting system are located and other
spaces of the building.
4. Close fireplace dampers.
43902-0-1021
IMPORTANT SAFETY INFORMATION
6. "Clothing or other flammable material should not be
placed on or near the appliance."
7. "Any safety screen, guard, or barrier removed for servicing
an appliance must be replaced prior to operating the
appliance" (see Clause 4.1.6).
8. "Installation and repair should be done by a qualified service
person. The appliance should be inspected before use and
at least annually by a professional service person. More
frequent cleaning might be required due to excessive lint
from carpeting, bedding material, et cetera. It is imperative
that control compartments, burners, and circulating air
passageways of the appliance be kept clean."
9. The instructions for an appliance optionally for use
with glass doors (or equivalent) shall state that, "Only
doors certified with the appliance shall be used."
10. The instructions for an appliance not intended for use
with glass doors (or equivalent) shall emphasize that
the appliance is not for use with glass doors.
11. Where applicable, provide a means by which the consumer
can identify the barrier, (such as graphic representation,
clear description, or reference marking).
5. Turn on clothes dryers and any appliance not connected
to the venting system. Turn on any exhaust fans, such
as range hoods and bathroom exhausts, so they are
operating at maximum speed. Do not operate a summer
exhaust fan.
6. Follow the lighting instructions. Place the appliance
being inspected into operation. Adjust the thermostat
so appliance is operating continuously.
7. Test for spillage from draft hood equipped appliances
at the draft hood relief opening after 5 minutes of main
burner operation. Use the flame of a match or candle.
8. If improper venting is observed during any of the
above tests, the venting system must be corrected
in accordance with National Fuel Gas Code, ANSI
Z223.1/NFPA and/or National Gas and Propane
Installation Code, CSA B149.1.
9. After it has been determined that each appliance
connected to the venting system properly vents when
tested as outlined above, return doors, windows, exhaust
fans, fireplace dampers and any other gas-fired burning
appliance to their previous conditions of use.