F14 Sensor type selection
Setting the type of accessory for controlling the operator.
F18 Additional light
Output on contact 10-E.
Flashing light: it fl ashes during the gate's opening and closing phases.
Cycle: external light for increased lighting of the driveway, it stays lit from the beginning of the opening until
complete closing, including the waiting time before the automatic closing.
F19 Automatic closing time
The automatic-closing wait starts when the opening limit switch point is reached and can be set to between
1 and 180 seconds. The automatic closing does not activate if any of the safety devices trigger when an
obstruction is detected, or after a total stop, or during a power outage.
F20 Automatic closing time
after a partial opening
The wait before the automatic closing starts after a partial opening command for an adjustable time of between
1 s and 180 s.
The automatic closing does not activate if any of the safety devices trigger when an obstruction is detected, or
after a total stop, or during a power outage.
 The F19 function must not be activated.
F21 Prefl ashing time
Adjusting the pre-fl ashing time for the fl ashing light connected to 10-E before each maneuver. The fl ashing time
is adjustable from one to ten seconds.
F28 Travel speed
Setting the gate's opening and closing speeds, calculated as a percentage.
F30 Slow-down speed
Setting the gate's opening and closing slow-down speed, calculated as a percentage.
F33 Calibration speed
Setting the speed only for the gate's calibration phase; calculated as a percentage.
F34 Travel sensitivity
Adjusting obstruction detection sensitivity during gate travel.
F35 Slow-down sensitivity
Adjusting obstruction detection sensitivity during slow-down.
F36 Adjusting partial
opening
Adjustment as a percentage of total travel, during gate opening.
 This function appears only is the Encoder function is activated.
0 = command with transponder sensor or magnetic card reader /
1 = for control with the keypad selector (default).
0 = Flashing light (default) / 1 = Cycle
OFF = Deactivated (default) / 1 = 1 second / ... / 180 = 180 seconds
OFF = Deactivated / 1 = 1 second / ... / 10 = seconds (default) / ... / 180
= 180 seconds
OFF = Deactivated (default) / 1 = 1 second / ... / 10 = 10 seconds
50 = Minimum speed / ... / 100 = Maximum speed (default)
10 = 10% motor's slow-down speed (minimum)/ ... / 20 = 20% motor's
slow-down speed ( default )/ ... /30 = 30% motor's slow-down speed
(maximum)
20 = 20% of the motor's speed; / ... / 40 = 40% of the motor's speed
10 = maximum sensitivity / ... / 100 = minimum sensitivity (default)
10 = maximum sensitivity / ... / 100 = minimum sensitivity (default)
10 = 10% of the gate travel (default) / ... / 80 = 80% of the gate travel