COMMAND AND CONTROL DEVICES
WARNING! For the system to work properly, before fi tting any plug-in card, such as the AF or R800 one, you MUST
CUT OFF THE MAINS POWER SUPPLY and, if present, disconnect any batteries.
Connector for GSM
module (UR042).
 The GSM connector
does not work, if
the RGP1 module is
connected.
Connector for AF card (AF868 or
AF43S) for remote control.
Blue
White
To be able to snap in the cards into the dedicated connectors, remove the card cover.
Black
Red
Connector for the R700 card
(for using the transponder
or the card reader) or for
the R800 card (for using the
keypad selector).
Keypad selector.
Transponder or card reader.
M E
C A
OPEN-CLOSE-INVERT function
(step-step) from control device
(NO contact). Alternatively, in the
functions programming, you can
activate the OPEN-STOP-CLOSE-
STOP (sequential, etc.). See
function F 7.
OPEN or PARTIAL OPENING
function from control device (NO
contact). See function F 8.
STOP button (NC contact). For
stopping the gate while excluding
automatic closing. To resume
movement press the control
button or use another control
device. See function F1.
Antenna with RG58 cable for
remote control.
R700 / R800
AF

Publicité

loading

Ce manuel est également adapté pour:

Bxv serieBxv sdn6vBxv sdn10v