Télécharger Imprimer la page

Ecolab DM Modular 20 Mode D'emploi page 73

Publicité

Les langues disponibles

Les langues disponibles

4.5
Alarms
If an alarm is triggered, the display colour will change to red and will flash,
alternating between red and white.
If the water faucet
is filled without request of the operator (for example at beverage mode).
The cause / troubleshooting is disciped here:
messages and incidents" on page 35. The display colour will flash further in
blue.
Communicate optionally to an authorized service technician of firm Carlsberg.
Restart Cleaning Module:
To restart the cleaning module, press keys 1,2 and 4 for seven seconds.
4.5.1
Alarm - Water valve
If the mixing container will be filled at beverage mode, a slashed faucet symbol is
displayed and the display will flash between green and blue.
If there is a active fault message a further slashed faucet is displayed the display will flash
between red and blue.
Fig. 25: Alarm - Water valve
4.5.2
Alarm - Alarm - Error: Compressor
Fig. 26: Alarm level - ERROR: Compressor
1
Current consumption to high at start.
2
Compressor runs continuously for 15 min.
3
Compressor running time higher than 75 % in one hour.
Ä Chapter 6.2.1 „Display error messages and incidents" on page 35, Fig. 32.
See
41710225´7, 1, en_GB
is displayed, the faults occours that the mixing container
29
Control / Visualisation
Alarms > Alarm - Alarm - Error: Compressor
Ä Chapter 6.2.1 „Display error
Rev. 03-01.2017