Configuration parameters per functional blocks
Equipment – Continue
Alarms
Alarm severity
The severity of each alarm is configurable individually with the following
attributes: major, major reverse, minor, minor reverse, none, none reverse
Alarm Persistence
Persistence for the appearance: X = 1, 3, 10 or 30s
Persistence for the disappearance: Y = 01, 3, 10 or 30s
Loops
Mismatch of remote indication loops 1 and 2 validated or not
(use of bits 1 to 4 of byte S1)
Centre site (yes/no)
Routing
Authorization to transmit traps to the management: declaration of the
manager addresses (10 addresses possible)
Tables of configured static routes
Putting ports into service: Ethernet, PPP1, PPP2, PPP3 or PPP4
Enabled / Disabled (port by port)
Port addressing (port by port) :
Interface IP address
Subnetwork mask
Destination IP address (PPP interface only)
Management paths (port by port – PPP only):
Options: MNGT, DCC1_A, DCC1_B, DCC1_C, DCC1_D
RIP routing validated or not (port by port)
Table 2-6 – Configuration parameters (6/6)
No reproduction or communication without the written consent of SAGEM SA
Installation and User Guide - N56717020101
2 - OPERATION
Default
value
See tables
2-9 to 2-11
X = 3s
Y = 3s
Not validated
No
Not configured
Disabled
0.0.0.0
0.0.0.0
0.0.0.0
Not configured
Not validated
Page A2-7