8.

Assembly Instructions

8.1
Drill the holes.
The following does not apply for hydraulic fittings and models with battery
operation:
8.2
Remove the perforated plate for inserting the cable.
8.3
Cut a suitable niche in the wall. The wall niche depth must be 95 mm (before tiling).
8.4
Insert the flush mounting cabinet in the wall niche.
8.5
Mark the drill holes.
8.6
Drill the mounting holes and push the dowels into the holes.
8.7
Mount the flush mounting cabinet in the wall niche provided for this purpose.
The following does not apply for hydraulic fittings and models with battery
operation:
8.8
Guide the ends of the cables into the flush mounting cabinet. Let the cables hang out
of the flush mounting cabinet approx. 50 cm.
8.9
Connect the water supply. Hold the function block with a open-jaw wrench.
8.10 Open the water volume regulator with a screwdriver, 8 mm blade width.
Caution!
Do not remove the circlip.
The water volume regulator is open when the regulating screw comes into contact
with the circlip.
8.11 Flush the pipes in compliance with DIN 1988.
Place the protective earth cable into the flush mounting cabinet in such a way that it
does not get kinked or otherwise damaged.
8.12 Mount the shell protector. Fix the position of the shell protection with the screws
supplied (a).
Important!
Wall assembly dimensions
min.
6 mm
max. 55 mm
Important!
Size of gap y between tiles and shell protection
min. 1 mm
max. 3 mm