schmalz Pompe X SXPi15 Notice D'utilisation page 82

Table des Matières

Publicité

Counter
140
0x008C cc1
Vacuum-on counter
141
0x008D cc2
Valve operating counter
142
0x008E cc3
Condition monitoring counter
Erasable vacuum-on counter
143
0x008F ct1
144
0x0090 ct2
Erasable valve operating counter
145
0x0091 ct3
Erasable Condition monitoring counter
Condition Monitoring [CM]
Condition monitoring
146
0x0092
147
0x0093
Leakage area
Evacuation time t
148
0x0094
Evacuation time t
149
0x0095
Energy Monitoring [EM]
155
0x009B
Air consumption per cycle in percent
J. Schmalz GmbH
4 bytes
0 - 999 mio
4 bytes
0 - 999 mio
4 bytes
0 - 999 mio
4 bytes
0 - 999 mio
4 bytes
0 - 999 mio
4 bytes
0 - 999 mio
1 byte
0 - 255
1 byte
0 - 255
2 bytes
0 - 65.535
0
2 bytes
0 - 65.535
1
1 byte
0 - 100
ro
0
Not erasable
ro
0
Not erasable
ro
0
Not erasable
ro
0
To reset this counter must "1" be sent to Index 0x007A
ro
0
To reset this counter must "1" be sent to Index 0x007A
ro
0
To reset this counter must "1" be sent to Index 0x007A
0 = no warning
1 =Valve protection aktiv
ro
0
2 =Evacuation time longer than t-1
4 = Leakage rate higher than -L-
8 = H1 in gripping cycle
0 = no actual value
1 = Leakage of last sucking cycle is >200mbar/s
ro
0
2 = Leakage of last sucking cycle is between 133 ... 200mbar/s
4 = Leakage of last sucking cycle is between 67 ... 133mbar/s
8 = Leakage of last sucking cycle is <67mbar/s
ro
0
Time from start of sucking to H2 [ms]
ro
0
Time from H2 to H1 [ms]
ro
0
Air consumption of last sucking cycle [%]