Benning MM 1-1 Notice D'emploi page 26

Masquer les pouces Voir aussi pour MM 1-1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
7.7 Capacity ranges (BENNING MM 1-2/ 1-3)
Conditions: Discharge capacitors and apply them according to the specified
polarity.
Note:
To increase measuring accuracy for small capacitors, note the
displayed value of the multimeter with open measuring lines and
subtract the remaining displayed value from the measured value of
the capacitor.
Cunknown = Cmeasured value - Cremaining
Overload protection for capacity measurements: 600 V
Measuring range
2 nF
20 nF
200 nF
2 µF
20 µF
200 µF
2 mF*
* < 10 digits in case of fluctuating indication
7.8 Frequency ranges (BENNING MM 1-2/ 1-3)
Overload protection for frequency measurements: 600 V
Minimum pulse width > 25 ns; operating cycle limitation > 30 % and < 70 %
Measuring
Resolution
range
2 kHz
1 Hz
20 kHz
10 Hz
200 kHz
100 Hz
2 MHz
1 kHz
20 MHz
10 kHz
7.9 Temperature ranges °C (BENNING MM 1-3)
Temperature measurements (BENNING MM 1-3) are possible by means of the
enclosed temperature measuring adapter only.
Overload protection for temperature measurements: 600 V
Measuring range
-20 °C ~ 0 °C
1 °C ~ 100 °C
101 °C ~ 500 °C
501 °C ~ 800 °C
*
The measuring accuracy of the K-type temperature sensor has to be added
to the specified measuring accuracy.
Wire temperature sensor (type K):
The measuring accuracy applies to stable ambient temperatures < ± 1 °C. After
a change of the ambient temperature of ± 2 °C, the measuring accuracy data
will apply after 1 hour.
7.10 Temperature ranges °F (BENNING MM 1-3)
Temperature measurements (BENNING MM 1-3) are possible by means of the
enclosed temperature measuring adapter only.
Overload protection for temperature measurements: 600 V
Measuring range
-4 °F ~ 32 °F
33 °F ~ 212 °F
213 °F ~ 932 °F
933 °F ~ 1472 °F
*
The measuring accuracy of the K-type temperature sensor has to be added
to the specified measuring accuracy.
Wire temperature sensor (type K):
03/ 2019
Resolution
1 pF
10 pF
100 pF
1 nF
10 nF
100 nF
1 µF
Measuring accuracy for 5 V
± (0.01 % of the measured value + 1 digits)
± (0.01 % of the measured value + 1 digits)
± (0.01 % of the measured value + 1 digits)
± (0.01 % of the measured value + 1 digits)
± (0.01 % of the measured value + 1 digits)
Resolution
Resolution
BENNING MM 1-1/ 1-2/ 1-3
Measuring accuracy
± (1.9 % of the measured value + 8 digits)
± (1.9 % of the measured value + 8 digits)
± (1.9 % of the measured value + 8 digits)
± (1.9 % of the measured value + 8 digits)
± (1.9 % of the measured value + 8 digits)
± (1.9 % of the measured value + 8 digits)
± (1.9 % of the measured value + 8 digits)
max.
eff
1 °C
1 °C
1 °C
1 °C
Measuring range: - 60 °C to 200 °C
Measurement accuracy: ± 2 °C
1 °F
1 °F
1 °F
1 °F
Measuring range: - 76 °F to 392 °F
eff
eff
Sensitivity
> 1.5 < 5 V
> 1.5 < 5 V
> 1.5 < 5 V
> 2 < 5 V
> 2 < 5 V
eff
Measuring accuracy*
± (2 % + 4 °C)
± (1 % + 3 °C)
± (2 % + 3 °C)
± (3 % + 2 °C)
eff
Measuring accuracy*
± (2 % + 8 °F)
± (1 % + 6 °F)
± (2 % + 6 °F)
± (3 % + 4 °F)
eff
eff
eff
eff
eff
17