ERROR MESSAGES
E1
Calibration error
E3
The Encoder does
not work
E4
Service test failure
error
E7
Work time expired
E8
Door lock open
E9
Maximum number
of closing obstacles
E10
Maximum number
of opening obstacles
E11
Maximum number
of obstacles
E12
Main power supply
missing
E14
Communication
error
E15
Incompatible remote
control
E16
Slave door open
E17
No communication
from the RIO system
E18
RIO system not
configured
Interruption of the boom travel calibration due to the presence of an obstruction.
The Encoder is disconnected.
The Encoder is broken.
Presence of an obstruction within the range of the photocells.
The photocells are not correctly connected or configured.
The photocells are faulty.
Finished the maximum work time set.
The operator is released.
The maximum number of obstacles detected consecutively has been exceeded
The maximum number of obstacles detected consecutively has been exceeded
The maximum number of obstacles detected consecutively has been exceeded
Configured on the wrong RSE port.
The transmitter used is not CAME.
The coding set is different from that of the transmitter.
The transmitters are TWIN and have different KEY BLOCK.
The SLAVE operator is released.
The wireless module is not plugged into the connector on the control board.
The wireless module is broken.
The wireless system has not been configured.
The wireless devices have not been configured.