7. MAINTENANCE

In order to ensure optimal operation and extend the lifetime of your Cinderella GAS you will need to set aside a
little time for preventive maintenance. Good maintenance routines will result in lower operating costs and cause
less wear on the product. There are some simple tasks that you should perform regularly and some that you
should perform annually or after 500 incinerations (1 pack of bowl liners).
NB!
The power should be disconnected when performing all servicing and maintenance of the toilet.
Cleaning frequency might need to be increased if toilet is in daily use. Some medication might affect functio-
nality and regular burning of sanitary products containing plastic might necessitate more frequent cleaning &
maintenance.

7.1 REGULAR MAINTENANCE

7.1.1 EMPTYING THE ASH CONTAINER

Recommended frequency: Weekly
1. Make sure that the incineration process has finished and the toilet has cooled down. The fan must have
stopped.
2. Remove the front cover and rotate the ash container until the handle is pointing straight towards you. The
flashing red and yellow lights indicate that the ash container is out of position. The display will read "Ash
container out of position".
3. Remove the insert (the innermost bowl) and dispose of the ash. Pour hot water into the insert and leave it
for about 30 minutes, before cleaning with a brush (do not use any sharp tools).
4. Put the insert back into the ash container and place the container back into the toilet by rotating the handle
to the left, until it stops. The red and yellow lights will turn off. The display reads "Ready for use" when the
container is in the correct position.
5. Place the front cover back on toilet.
6. Open the lid. Press and hold the Start button to open the toilet in the washing position. Without placing a
bowl liner or toilet paper in the toilet, pour 1/4 gallon (1 litre) of water into the toilet. You may also use water
to clean the bowl. Close the toilet lid then press the Start button to start the incineration process. The water
inside the insert will start to boil and the steam will clean the catalyst.
NB!
Remove the ash container only when it is cool and toilet is not in operation