8.2 FAQ

DURING A POWER OUTAGE
If waste is burning when there is a power outage, you may get smoke and odours on the outside. The toilet
exterior may become slightly warm due to the fact that the fan is operating without mains power. The in-
cineration will not automatically start when the mains power returns. You will have to manually restart the
toilet and start a new incineration cycle. If the power outage is expected to last for a longer period of time, it
is important that you empty any waste that is in the toilet, as this could damage the toilet if it remains there
for a long time. NEVER USE THE TOILET DURING A POWER OUTAGE.
ODOURS IN THE ROOM
Can have several causes:
Failure to use a bowl liner each time the toilet is used or improper use of the liner. The airflow may be bloc-
ked. Inspect the outlet pipe and chimney cap. Check that the installation has been performed in accordance
with the installation manual. Too much restriction in the outlet air could cause back pressure and cause
odours inside.
The exhaust pipe may be clogged. See page 12, Basic Cleaning of the Catalyst.
The catalyst may be clogged. See page 12 Advanced Cleaning of the Catalyst.
ODOURS OUTSIDE
The causes may be the same as for inside the room plus:
The catalyst has been activated by the heat. When the toilet is cold it can take a few minutes before the cata-
lyst starts to work. The catalyst may be faulty. Contact your servicing provider.