MAINTENANCE:
Brio Top has been designed to reduce maintenance requirements to a minimum. Always observe the
following instructions to ensure prolonged efficiency of the device:
- never allow the device to reach temperatures below 4° C; if this is not possible, ensure that all the water
in the circuit is drained to prevent damage to the plastic housing of the device if ice forms;
- if the pump is equipped with filters on intake, check their condition periodically;
- always ensure that the cover is closed properly to avoid the ingress of water from outside;
- disconnect the power and drain water from the system when the system is not to be used for a prolonged
period;
- before using the device with liquids other than water, contact the manufacturer for further information;
- never perform work with the device open;
- before removing the device cover, wait for 3 minutes to enable discharge of the capacitors.
CAUTION: the device does not contain components that may be repaired or replaced by the
final user. Therefore do not remove the protection cover of the el ectronic board to avoi d renderi ng
the guarantee null and void.
Date of i nstallation
Client
Pump brand-model
Serial N° Brio Top
FACTORY SETTING S ON INSTALLATION
Mode
Pmin
Pmin2
Pmax
Reset
Reset
Prot.24H
Prot.4°C
Stop delay
Imax
Plimi t
Aux. Con.
Deact. thresh.
Notes
..../..../.......
Bar
Bar
Bar
Mi nutes
Test
Seconds
A
Bar