- mode P+P (pressure + pressure) = in this mode the pump operating mode is controlled within two
pressure levels (Pmin e Pmax); when the lower pressure threshold is reached (Pmin) the pump is started
up, while it is stopped when the upper pressure threshold (Pmax) is reached. In this configuration, the use
of an expansion vessel is essential, sized a ccording to the system requirements and type of pump.
In both operating modes, the device protects the pump from dry running in the absence of water on
intake, by means of a combined control on flow and pressure.
Operation of twin pumping units is admissible only in "P+P" mode.
TECHNICAL DATA
Mains power:.................................... single phase 230Vac ±10% - 50/60Hz
Motor output:.................................... single phase 230V~
Maximum motor power................................ 2200W – 3Hp
Maximum motor phase current:...............16Arms
Maximum admissible pressure:................1000 KPa (10 bar)
Maximum liquid temperature................. 30°C
Max. ambient temperature.......................55°C
Pressure drop:.................................... 0.7 Bar at 100 l/min
Hydraulic connection...........................1" M-M (1"F inlet; rotary on request)
Protection rating:.................................IP 65
Weight.............................................0.7 Kg
Dimensions........................................225x150x115 mm
Type of action....................................1 (a ccording to EN 60730-1)
FUNCTIONS
√ Automatic start-up and shutdown of the pump.
√ Operation with twin units operating alternately.
√ Easy and precise control of working pressures via the display.
√ Protection against dry running with automatic reset
√ Installable in both horizontal and vertical positions
√ Digital indicator of pressure and absorbed current on display
√ Operating status indicator leds (mains, error, pump running)
√ Digital input for float or remote control connection
√ Configurable relay output
√ Removable electrical terminals to facilitate wiring.
√ Alarm log
PROTECTIONS
√ Dry-running
√ Motor current control protection
√ Overpressure cut-out
√ Anti-freez e protection
√ Prevention of mechanical pump part seizure