Mcdonald's Alert Guide - Henny Penny 100 Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

McDonald's Alert Guide

FILTER ERROR "IS POT FILLED"
= During the AIF procedure, the display may show
"IS POT FILLED? If the vat is full, press the √ button to resume normal operation.
If the vat is not full, press the X button for "NO" and the display then shows
"FILL POT FROM DRN PAN". Follow the prompts.
Note: To avoid getting this message make sure filter pan is cleaned at least daily,
filter pad is changed, make sure JIB is full and that "O" rings are in good condition.
"CHECK PAN"
= Filter pan is not locked in place.
"CHANGE FILTER PAD"
= Filter pad has not been changed within 25 hour time
period.
ELECTRIC FRYERS ONLY! "E-31" HEATING ELEMENTS ARE UP
= Heating elements
have been left up during maintenance filter. Lower heating elements.
ELECTRIC FRYERS. "E-10" HI LIMIT TRIPPED
= Allow heating elements to cool and
reset the high limit by using a small screwdriver or Allen wrench and gently push it
into the hole in the heating element hinge; if high limit does not reset call for
service. See ELECTRIC FRYERS photo below.
GAS FRYERS. "E-10" HI LIMIT TRIPPED
= Allow fryer to cool and
reset the high by
pressing
the red reset button under the right side of the
controls; if high limit does
not reset call for service. See GAS FRYERS photo below.
ELECTRIC FRYERS
GAS FRYERS
GAS FRYERS ONLY! E-20" "NO DRAFT" "CHECK
HOOD"
=
Check the fryer flue and
hood system for obstructions; have the vacuum switch checked
FRYER ON BUT NOT HEATING
= Vat unplugged or circuit breaker off
Henny Penny Technical Support Hotline:
1-800-417-8405
or 937-456-8405