Hydraulic System - SFA SANIPUMP ZFS 71 Série Mode D'emploi

Pompe submersible pour évacuation des eaux usées
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
Wiring diagram:
MAINS
3~ 400 V/50 Hz
L1
L2
L3
Fuse
Motor
protection
Motor
relay
U1
V1
W1
1
2
3
M
3~
400 V
50 Hz
Connection of the thermal winding cover :
- Control loop : T1 and T2 must be connected in a switching device in such a way, that the following function
is guaranteed: When the temperature sensors respond, the pump is switched off until the tempera-ture has
dropped again. Now the pump is switched on again.
- Clipping circuit : T2 and T3 must be connected in a switching device in such a way, that the following
function is guaranteed: When the temperature sensors respond, (failure of the control loop), the pump is
switched off and can be restarted by hand solely. The pump may only be restarted after an er-ror analysis
has been conducted and the cause of malfunction has been eliminated.
Connection to the switching device PS1-LCD and PS2-LCD :
Switching
device
Switching device
20
Pump
T1

5.2 Hydraulic system

These pumps are not to be mounted in dry installation, since a minimum
water level up to the bottom edge of the motor housing is prescribed by
the guideline on protection against explosion.
Installation with supporting ring :
- Mount supporting ring to intake flange of the pump and install pump. Ensure stability of the pump.
- Optionally connect pressure side by means of flange DN 50 or thread (The pump is equipped with a female
thread G2 and a flange DN 50).
- If a hose is to be laid on the pressure side, kinks are to be avoided.
- Avoid kinks during the laying of the supply cable. Lay supply cable without tensile loading and without
causing chafe marks.
Installation for shaft fitting :
- Position pipe clamp on inner rim of the shaft and loosely fix it with two screws.
10
Thermal winding protection
Control circuit Clipping circuit
TB1
TB2
TB3
4
5
6
Green/Yellow
PE conductor
PS1-LCD
Pump 1
21
22
T2
T3
PS2-LCD
Pump 1
31
32
33
T1
T2
T3
Pump 2
38
39
40
T1
T2
T3

Publicité

Table des Matières
loading

Table des Matières